GE 263 Benutzerhandbuch

Seite von 44
Troubleshooting
39
Rev A
Troubleshooting
Ultramax Series Controller Troubleshooting
Problem
Possible Cause
Solution
ERR 1 is displayed.
Program settings have been corrupted.
Press any key and reset model number.
ERR 3 is displayed.
Controller does not know the position of 
the camshaft. Camshaft should be 
rotating to find Home position.
Wait for two minutes for the controller to 
return to Home position. The hourglass 
should be flashing on the display 
indicating the motor is running.
Camshaft is not turning during ERR 3 
display.
Check that motor is connected.
Verify that motor wire harness is 
connected to motor and controller 
module.
Verify that optical sensor is connected 
and in place. 
Verify that motor gear has engaged cam 
gear.
If everything is connected, try replacing 
in this order:
—Wire harness
—Motor
—Optical sensor
—Controller
If camshaft is turning for more than five 
minutes to find Home position:
Verify that optical sensor is in place and 
connected to wire.
Verify that camshaft is connected 
appropriately.
Verify that no dirt or rubbish is clogging 
any of the cam slots.
If motor continues to rotate indefinitely, 
replace the following components in this 
order:
—Wire harness
—Motor
—Optical sensor
—Controller
Time of Day incorrect.
Power failure occurred.
Press SET to reset the time display.