Each module may be given a descriptive name with the command below. The show 
command follows with the new name bolded. Each new slot name may also be displayed 
with individual show commands in each slot context. 
 
 
 
fiberdriver(slot/1.3)# description EDFA-1 
fiberdriver(slot/1.4)# description EDFA-2 
fiberdriver(slot/1.3)# up 
fiberdriver(chassis/1)# show 
        Model: NC316BU-16 
         Name: NC316BU-1 
      Temp(C): 25 
  Temp Min(C): 5 
Temp Limit(C): 55 
 
PS1: DC Bad  PS2: AC Good 
Fan1: good  Fan2: good 
Fan3: good 
Chassis Traps: on  Slot Change Traps: on  Module Specific Traps: on 
   Port Traps: on         Link Traps: on         Loopback Traps: on 
    LIN Traps: on  Port Change Traps: on       Port Diags Traps: on 
 
Number Of Slots: 16 
Hardware Revision: 1 
 
Slot  Model            Name                    Serial Number 
====  ===============  ======================  ============================ 
1.2   EM316LNXNM-OT    EM316LNXNM-OT at 1.2    00:20:1a:02:48:28 
1.3   EM316EDFAv       EDFA-1                  N/A 
1.4   EM316EDFA        EDFA-2                  N/A 
1.5   EM316E1MUX4RM    EM316E1MUX4RM at 1.5    12:34:56:78:90:15 
1.6   EM316DPAD821     EM316DPAD8 at 1.6       N/A 
1.7   EM316EFE1MUXRJv  EM316EFE1MUXRJv at 1.7  00:20:1a:77:88:99 
1.8   EM316EFE1MUXRJ   EM316EFE1MUXRJ at 1.8   00:20:1a:77:88:99 
 
fiberdriver(chassis/1)#