Lucent Technologies 585-210-940 Benutzerhandbuch
Installing Mirrored Systems
CentreVu CMS Release 3 Version 8 Disk-Mirrored Systems
Factory installation procedures for disk mirroring
29
.
Step 3: Install the
application
software
application
software
2
Install application software as instructed in the
CentreVu CMS R3V8
Software Installation and Setup (585-210-941) document. That will mean
installing the following packages in order:
installing the following packages in order:
●
Common Desktop Environment (CDE)
●
SunLink
*
HSI/S drivers (if using HSI/S ports)
●
NTS drivers (if using NTS ports)
●
X.25 (if using X.25 switch links)
●
INFORMIX
†
SQL (optional)
●
INFORMIX SE
●
INFORMIX ESQL
●
INFORMIX ILS
●
Solstice DiskSuite
●
Sun Solaris patches
Partitioning (Note: Never change the default size of the
overlap slice!)
CMS R3V8
4.2-GB Disk
CMS R3V8
9.1-GB Disk SCSI
(E3000) and FC-AL
(E 3500)
Disk
Type
Part
Tag
Flag
Size
(cyl.)
Starting
Cylinder
Size
(cyl.)
Starting
Cylinder
Boot
0
boot disk 1: / or root
boot disk 2: unassigned
boot disk 2: unassigned
wm
1023
0
616
0
1
unassigned
wm
7
1023
7
616
2
overlap
or backup
wm
3880
0
4924
0
3
unassigned
wm
1879
1030
3716
623
4
swap
wm
971
2109
585
4339
5-7
unassigned
wm
0
0
0
0
Nonboot
0
unassigned
wm
2
0
2
0
1
unassigned
wm
3878
2
4922
2
2
overlap
or backup
wm
3880
0
4924
0
3-7
unassigned
wm
0
0
0
0
*
SunLink is a trademark of Sun Microsystems, Inc.
†
INFORMIX is a registered trademark of Informix Software, Inc.