USING  THE  M-20  CONTROL  FUNCTIONS:
The M-20 controls are designed for utility and repeatability under varying conditions and 
make only subtle impact on the basic character and accuracy of the speaker.   We encourage 
you to experiment with fine tuning the system to your particular requirements.
POWER INDICATORS: 
Two LED’s are located to the immediate   left   of   the   power   switch   on   the   M-20 Control Amplifier:. 
The top (green) LED lights up indicating there is AC power to the amplifier and the POWER SWITCH is turned 
“On”.  
The lower (red) LED indicates a clipping or overload condition.   Occasional flashing of this 
indicator is a gentle warning you are reaching the system’s limits.   If the red LED glows continually, 
severe clipping is occurring and the input   signal or system   gain should be reduced to avoid the risk 
of possible system damage.
SYSTEM  STATUS  DISPLAY:  
Located in the center of the front panel, a unique system status display informs you of the 
operating state of your system. Three small LED’s(green for average SPL, yellow for AC line voltage, 
and blue for heat sink temperature)respond to your setting the square MODE switch to the right of 
the System Status Display to the desired mode.   
SPL:   This is a reading of the long term average sound pressure level calibrated at 2 meters from the M-20 
monitor, and derived from the amplifier output voltage.   Peak sound levels are ignored.   The readout is 
designed to report overall listening levels and to help realize consistent   monitoring from hour to hour, 
session to session and room   to   room.     Levels   under   68 dB   are   shown   as “00”;   levels   over   120 dB are 
shown as “HI”.   Since monitoring level has   a profound influence   on   the   perception   of   sonics,   
periodically   checking SPL helps to assure consistent   results.         
VAC:   This is a reading of the AC power line voltage being supplied to the M-20.   It is useful for assuring 
that power conditions are correct and sufficient for all the equipment on the circuit.   Sustained readings 
below 110 V may   limit   your   maximum   output   levels,   and   could   indicate that the AC   circuit is 
overloaded.     Continuous   readings above 125 V indicate an   AC circuit   problem, which   could   lead   to   
amplifier  failure.   
TMP:   This   is   a   reading of   the   output   heat   sink temperature in Centigrade.   Typically, you should   
expect this to   run   between   40°C   and   60°C,   depending   on   listening and ambient conditions.     If you 
find that   your Control Amplifier unit tends to run hotter than 60°C, it is recommended that   you improve 
the ventilation around it.     The M-20 Control Amplifier contains a protection circuit that automatically 
shuts the amplifier down if the heat sink temperature reaches 100°C. 
SENSITIVITY:   
This function controls input sensitivity with settings at -10dB, -3dB, +4dB, +11dB and (M)ute to provide 
noise-free, consistent gain matching with a wide variety of equipment.   The proper setting is the 
lowest sensitivity   possible (highest dB number) which allows the speaker to reach the maximum 
desired output without source clipping.   Professional devices typically specify full output at +4dB, 
most consumer audio products reach full output at -3dB; most computer sound cards at -10dB.   Consult 
the owner’s manual of the source device driving to the M-20 Control Amplifier for its output level 
specifications and set the SENSITIVITY control   accordingly.