LevelOne 4100 Benutzerhandbuch

Seite von 38
 34
Configure the frequencies of disconnect tone. It is used to detect the incoming 
disconnect tone by FXO port.    
Due to the disconnect tone is usually composed by two different frequencies, 
you must get these frequencies from your local telecom standards.  Key the 
frequencies by Hz in Frequency1 and Frequency2 fields. 
 
Tone On-Off Duration Setting
Configure the cadence of disconnect tone. It is used to detect the incoming 
disconnect tone duration by FXO port. 
If you know each duration value, turn CP Tone Auto Learning off.  And, 
Key the time of tone on duration in Tone-On field. 
Key the time of tone off duration in Tone-Off field. 
If you do not know each duration value, enable CP Tone Auto Learning.  And, 
Save FXO settings.   
Reboot the system.   
Make a call through FXO port.  After the callee reply and disconnect, wait for 10 
seconds.  Enter the FXO setting user interface again. You will find the Tone 
On-Off fields filled by values detected. 
Turn CP Tone Auto Learning off. 
 
Loop Current Shutdown Detection
Select “YES” if you want to detect the status of loop current in FXO port. If not, 
select “NO”
 
FXO Gain Control
These fields are used to decrease or increase the gains in FXO output and 
input channels.  Default gain values are all “zero”.   
When you make a call from IP to PSTN, adjust FXO Input Gain Control (To 
PSTN) to a lower value if PSTN cannot recognize your numbers dialed after 
hearing the PSTN dial tone.  For example, set “-6” to replace the default “0”.  
Always use “6” as a unit for your first trial and find a best suitable number then. 
When you make a call from PSTN to IP, adjust FXO Output Gain Control (To IP) 
to a lower value if IP cannot recognize your numbers dialed after hearing the 
dial tone.  For example, set “-6” to replace the default “0”. 
 
Click Save FXO Setting to save all settings to FXO port.