1.  Lift
 the ceiling tile nearest the grid 
rail in your desired sensor location. 
Guide one side of the C-clip over 
one edge of the grid rail. Providing 
firm support to the back of the 
grid rail with one hand (to prevent 
bending), firmly and carefully snap 
the second side of the C-clip over 
the edge of the rail.
2.  Uncoil
 sensor wire. Connect one 
end of the sensor cable to the 
plug on the sensor. Secure wire 
overhead and route it back to  
the system.
3.  Connect
 the other end of the 
sensor cable into one of the sensor 
inputs on the back of the system.
IR SENSOR INSTALLATION (cont’d)
1.  Screw
 the plastic mounting strip to 
a place high on the wall or in the 
middle of the solid ceiling. Mount the 
strip horizontally as shown above.
2.  Firmly
 snap the C-clip on the back 
of the IR sensor onto the plastic 
mounting strip with the sensor plug 
hanging down (if a wall mount) 
or toward the receiver location (if 
ceiling mount).
3.  Uncoil
 the sensor wire. Screw one 
end of the sensor cable to the plug 
on the sensor. Route the wire back to 
the system, securing it along  
the way.
4.  Connect
 the other end of the sensor 
cable to one of the sensor inputs on 
the back of the system.
 
wall 
mounting 
strip
c-clip
sensor plug
Suspended Ceiling Mount