Communication Settings
The default settings for the RS-232 COM port are as follows:
Baud Rate:
115,200
Parity:
None
Data bits:
8
Stop bits:
1
Flow Control:
None
RS-232 Connector Information
The pin-out for the RS-232 control port is as follows:
Pin
Description
1
No Connection
2
Receive Data
3
Transmit Data
4
No Connection
5
Ground
6
No Connection
7
RTS (Not needed if Flow Control set to None)
8
CTS (Not needed if Flow Control set to None)
9