GE PTDS650GMWT Benutzerhandbuch

Seite von 9
WARNING 
RISK OF FIRE
• To reduce the risk of severe injury or death, follow all installation instructions.
• Clothes dryer installation must be performed by a qualified installer.
• Install the clothes dryer according to these instructions and in accordance with local 
codes. In the absence of local codes, installation must comply with National Fuel Gas 
Code, ANSIZ223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, 
CSA B149.1.
• California Safe Drinking Water and Toxic Enforcement Act.
  
This act requires the governor of California to publish a list of substances known to the 
state to cause cancer, birth defects or other reproductive harm and requires businesses 
to warn customers of potential exposure to such substances. Gas appliances can 
cause minor exposure to four of these substances, namely benzene, carbon monoxide, 
formaldehyde and soot, caused primarily by the incomplete combustion of natural gas 
or LP fuels. Properly adjusted dryers will minimize incomplete combustion. Exposure 
to these substances can be minimized further by properly venting the dryer to the 
outdoors.
• This dryer must be exhausted to the outdoors.
• Use only 4” rigid metal ducting for exhausting the clothes dryer to the outdoors.
• DO NOT install a clothes dryer with flexible plastic ducting materials. If flexible metal 
(semi-rigid or foil-type) duct is installed, it must be UL listed and installed in accordance 
with the instructions found in “Connecting The Dryer To House Vent” on page 6 of this 
manual. Flexible venting materials are known to collapse, be easily crushed, and trap 
lint. These conditions will obstruct dryer airflow and increase the risk of fire.
• Do not install or store this appliance in any location where it could be exposed to water 
and or weather.
• Dryers installed in residential garages must be elevated 18” (46 cm) above the floor.
• Save these instructions. (Installers: Be sure to leave these instructions with the 
customer).
In the state of Massachusetts, installation must be performed by a qualifiedor 
licensed contractor, plumber, or gasfitter qualified or licensed by the state.
Installation
Instructions
Gas Dryer
06
Questions on Installation? Call: 1-800-GECARES (US)
or Visit our Web site at: www.GEAppliances.com (US)
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT-
 Save these instructions for 
local inspector’s use.
IMPORTANT-
 Observe all  governing codes 
and ordinances.
 Note to Installer - Be sure to leave these 
instructions with the customer.
• Note to Customer - Keep these instructions 
with your Use and Care Book for future 
reference.
• Before the old dryer is removed from service or 
discarded, remove the dryer door.
• Inspect the dryer exhaust outlet and straighten 
the outlet walls if they are bent.
• Service information and the wiring diagram 
are located in the control console.
• Do not allow children on or in the appliance. 
Close supervision of children is necessary when 
the appliance is used near children.
• Install the dryer where the temperature is 
above 50°F for satisfactory operation of the 
dryer control system.
LEVEL
8" PIPE WRENCH
10" ADJUS TABLE WRENCHES
 (x2)
TOOLS YOU
WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
M ATERIALS YOU WILL NEED
EXHAUST HOOD
FLEXIBLE GAS LINE CONNECTOR
SOAP SOLUTION
FOR LEAK DETECTION
PIPE
COMPOUND
DUCT TAPE
GLOVES
SAFETY GLASSES
4" DIAM METAL ELBOW
4" DUCT CLAMPS
OR
4" SPRING CLAMPS 
 (x2)
 (x2)
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
 KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
234D1113P002      31-16225-1   07/08/10 GE
Step 1 Verify Your Gas Installation (see section 2).
Step 2 Prepare the Area and Exhaust for Installation of  
New Dryer (see section 1).
Step 3 Check and Insure the Existing External Exhaust 
is Clean (see section 1) and Meets Attached 
Installation Specifications (see section 6).
Step 4 Remove the Foam Shipping Pads (see section 1).
Step 5 Move the Dryer to the Desired Location.
Step 6 Level Your Dryer (see section 8).
Step 7 Connect the Gas Supply (see section 3) and check 
for leaks (see section 4).
Step 8 Connect the External Exhaust (see section 7).
Step 9 Connect the Power Supply (see section 5).
Step 10 Check the Operation of the Power Supply, Gas   
Connections, and Venting.
Step 11 Place the Owners Manual and the Installation 
Instructions in a Location Where They Will Be 
Noticed By the Owner.
For Alcove or Closet Installation see section 9.
For Bathroom or Bedroom Installation see section 10.
For Mobile or Manufactured Home see section 11.
DESIGN