Ricoh GLD0-0025-01 Benutzerhandbuch

Seite von 202
also
 
writes
 
a
 
line
 
number
 
from
 
the
 
module,
 
which
 
indicates
 
the
 
line
 
at
 
which
 
the
 
condition
 
that
 
caused
 
the
 
message
 
occurred.
 
The
 
expanded
 
output
 
is
 
similar
 
to
 
this:
 
pdxtclnwork:
 
(aioxcwrk0139)
 
5016-001
 
The
 
command
 
option
 
-o
 
is
 
not
 
valid.
 
This
 
message
 
shows
 
that
 
the
 
error
 
resulted
 
from
 
a
 
pdxtclnwork
 
command
 
and
 
that
 
the
 
error
 
occurred
 
at
 
line
 
0139
 
of
 
the
 
module
 
aioxcwrk
.
 
Set
 
the
 
PDXT_INTMSGIDS
 
variable
 
to
 
1
 
to
 
include
 
module
 
and
 
line
 
number
 
information.
 
Remove
 
the
 
environment
 
variable
 
to
 
suppress
 
the
 
module
 
and
 
line
 
number
 
information.
 
Controlling
 
the
 
format
 
of
 
the
 
error
 
sheet
 
(PDXT_MSGxxxxxxx)
 
If
 
you
 
submit
 
a
 
Xerox
 
job
 
for
 
processing
 
in
 
a
 
combined
 
InfoPrint
 
Manager
 
and
 
InfoPrint
 
XT
 
installation
 
and
 
severe
 
errors
 
occur
 
that
 
prevent
 
InfoPrint
 
XT
 
from
 
generating
 
AFP
 
output,
 
InfoPrint
 
XT
 
generates
 
an
 
error
 
sheet.
 
InfoPrint
 
XT
 
uses
 
four
 
environment
 
variables
 
and
 
the
 
InfoPrint
 
Manager
 
line2afp
 
transform
 
to
 
generate
 
the
 
error
 
sheet.
 
Typically,
 
you
 
only
 
change
 
the
 
default
 
settings
 
for
 
these
 
environment
 
variables
 
if
 
you
 
use
 
a
 
medium
 
other
 
than
 
letter,
 
such
 
as
 
A4
 
paper:
 
PDXT_MSGFOLDCMD
 
Controls
 
how
 
the
 
message
 
lines
 
of
 
the
 
error
 
sheet
 
wrap
 
on
 
the
 
page.
 
InfoPrint
 
XT
 
uses
 
standard
 
input
 
(STDIN)
 
to
 
pass
 
the
 
messages
 
to
 
the
 
command
 
specified
 
by
 
the
 
environment
 
variable.
 
Then,
 
InfoPrint
 
XT
 
pipes
 
the
 
output
 
from
 
the
 
command
 
to
 
the
 
InfoPrint
 
Manager
 
line2afp
 
command.
 
If
 
you
 
do
 
not
 
set
 
this
 
variable,
 
InfoPrint
 
XT
 
uses
 
fold
 
-w
 
120
.
 
PDXT_MSGFONTDEF
 
Controls
 
the
 
font
 
definition
 
that
 
InfoPrint
 
XT
 
uses
 
to
 
generate
 
the
 
error
 
sheet.
 
If
 
you
 
do
 
not
 
set
 
this
 
variable,
 
InfoPrint
 
XT
 
uses
 
trc=no
 
chars=4282
.
 
PDXT_MSGFORMDEF
 
Controls
 
the
 
form
 
definition
 
that
 
InfoPrint
 
XT
 
uses
 
to
 
generate
 
the
 
error
 
sheet.
 
If
 
you
 
do
 
not
 
set
 
this
 
variable,
 
InfoPrint
 
XT
 
uses
 
F1MG0110
.
 
PDXT_MSGPAGEDEF
 
Controls
 
the
 
page
 
definition
 
that
 
InfoPrint
 
XT
 
uses
 
to
 
generate
 
the
 
error
 
sheet.
 
If
 
you
 
do
 
not
 
set
 
this
 
variable,
 
InfoPrint
 
XT
 
uses
 
P1A08682
.
Note:
  
When
 
InfoPrint
 
XT
 
generates
 
the
 
error
 
sheet,
 
it
 
also
 
writes
 
the
 
results
 
of
 
line2afp
 
transform
 
processing
 
for
 
the
 
error
 
sheet.
 
The
 
line2afp.lst
 
file
 
in
 
the
 
working
 
directory
 
for
 
the
 
job
 
contains
 
the
 
information.
 
The
 
default
 
working
 
directory
 
is
 
%PDXTWORKDIR%\jobs\
ServerName_JobIdentifier.
 
Environment
 
variables
 
for
 
directives
 
Two
 
other
 
InfoPrint
 
XT
 
environment
 
variables
 
are
 
specific
 
to
 
transform
 
directives
 
and
 
to
 
installations
 
that
 
use
 
Download
 
for
 
z/OS.
 
Because
 
other
 
considerations
 
for
 
their
 
use
 
exist,
 
this
 
publication
 
describes
 
them
 
in
 
individual
 
topics.
 
See:
 
v
   
v
   
 
Chapter
 
3.
 
Customizing
 
InfoPrint
 
XT
 
25