SC-1002 / 1012 / 1022-10 14  Installation Instructions 
2/20/08 
CP4997B 
ELECTRICAL CONNECTIONS CONTINUED   (ALL MODELS) 
BAT 
Plug installed 
this orientation 
6-P Terminal Block Plug 
(CP4956-06) 
RED 
#16 AWG BLK 
#18 AWG BRN 
+VDC Switching examples 
HORN 
RING 
SWITCH 
+VDC 
AUX 
SPLICE 
HORN 
RING 
SWITCH 
+VDC 
AUX 
Added 
SPDT 
Switch 
HORN 
HORN 
 
-
VDC 
switching 
example 
Must set AUX_P 
option switch 
MOMENTARY 
FOOT 
SWITCH 
AUX 
#22 AWG WHT 
15A Automotive 
Type Fuse 
25A Automotive 
Type Fuse 
Load 
Load 
Back of Unit 
RED  (Positive Supply) 
Recommended Wire Size 
Load 1 + Load 2 + 
8 for Amplifier 
Amps 
Size 
8 - 10 
#16 
10 - 15 
#14 
15 - 25 
#12 
Use next larger size if 
longer than 10 ft. 
25 - 28 
#10 
Load 1  and  Load 2 
Recommended 
Wire Size 
Amps 
Size 
5 - 10 
#16 
10 - 15 
#14 
15 - 20 
#12 
Use next larger size if 
longer than 10 ft. 
AWG see table 
AWG 
see table 
On  SC-1002 / 1012 
Unit enable must be connected 
unless option SW-2 is changed. 
See page 5. 
#18 AWG BRN 
Plug into unit first for 
terminal identification 
For Aux Input Connection 
 
If just a splice is made to 
vehicle horn circuit, the 
vehicles horn will also 
sound with the siren. 
#22 AWG 
ORG 
On  SC-1022 
Unit enable must be connected. 
Unit Enable 
(like an ON/OFF switch) 
Connect to positive circuit 
(fuse panel) controlled by 
ignition or other switch 
SIREN 
FUSE 
LT2 
NEG 
POS 
LT1 
ENA 
AUX
 
SPK 
SPK 
LITE 
FUSE 
Do not remove nut 
Do not remove nut