Faber M1024 Benutzerhandbuch

Seite von 127
 
Genie Monochrome Series-GigE Vision Camera 
Operational Reference    47 
Reset Mode 
•  Exposure starts immediately after a valid trigger. There is no jitter on the start of exposure. 
•  Exposure time is programmable or controlled by the trigger pulse width. 
•  Minimum exposure is 100 µs – maximum is 4 seconds, with control steps of 1µs.  
•  Sensor readout must complete before the next exposure can start. That is, exposure and readout are sequential. 
Therefore, the maximum frame rate is lower than for Synchronous mode. 
•  Any external trigger received before the previous exposure/read out sequence is complete is ignored. An 
application can elect to receive messages about ignored triggers. See 
" on page 63
 
 
Reset Mode Timing example for Genie M640 
 
Synchronization Mode via Sapera LT or GenICam Applications 
 
Sapera
 
Genie Sapera parameters for Synchronization Mode: 
ExposureAlignment = {Synchronous = 0, Reset = 1} 
In CamExpert, these parameters are available under the “Sensor” tab in the “Exposure Control” 
dialog box.  
See "Accessing Features with Sapera++ LT
.  
 
 
 
GenICam features for Synchronization Mode: 
SensorSynchronization = {Synchronous = 0, Reset = 1}