52    Operational Reference 
Genie Monochrome Series-GigE Vision Camera 
When an event mode is selected, its trigger output schematic or signal timing diagram is displayed, as well as any 
other additional parameters for the mode.  
For most event modes, the trigger output signal can be set to either Active Open (that is high with the load 
connected to a voltage source) or Active Closed (where current is drawn through the load). The output delay can be 
set from 0 to 4 seconds, in increments of 1 µs. The pulse duration can be set from 100µs to 4 seconds, in increments 
of 1 µs. 
 
Open and Close Output Settings 
You can open and close the output circuit using software rather than hardware events, to control external devices. 
To control the output setting with Sapera LT see 
"
" on page 
56
.  
 
 
 
Strobe On Start of Exposure Event Mode 
The Strobe On Start of Exposure event mode is used when controlling a strobe light using the Genie output pin. The 
exposure delay parameter is specified using the Sensor Parameters tab Exposure Control setting.  
For Synchronous mode, the exposure start timing is aligned to the line period of the sensor. This can delay the start 
of exposure by an amount of up to 31.77µs for the Genie M640. For more information on exposure synchronous 
time see 
"
" on page 43
.