Siemens CCMX1315-LP Benutzerhandbuch

Seite von 60
Configuration 
41 
Siemens Building Technologies
 
 
Fire Safety & Security Products 
 
01.2009
 
 
z
 
Recording by Alarm 
Configure "Alarm input setting" first. 
Then select the recording format: 
– 
Record source: choose JPEG or MPEG4 format 
– 
Recording frame 
Set the number of images to be recorded immediately after an alarm occurs.  
Images of the moment when an alarm occurs are not included. 
1, 2, 5, 10, 30 and 60 frames can be selected if JPEG format selected. No 
need for MPEG4 format 
– 
Recording cycle 
Set a time interval for alarm recording 1, 2, 5, 10, 30, 60, 90, 120 s can be 
selected for JPEG format, no need for MPEG4 format 
– 
Recording time: 
If MPEG4 is selected, please set the recording time to 2, 5, or 10 s. 
z
 
Recording by Motion 
Perform "Motion Detection Setting" first. 
All the other settings are same as recording by alarm as above. 
z
 
Recording by Network Loss  
Select network recording. After network loss, the network camera automatically 
stores images based on your settings. 
– 
Recording cycle 
Set a time interval for network recording. 1, 25, 10, 30, 60, 90, 120 s can be 
selected. 
 
2. 
Click the Save button under the items. 
Î
 
Changes are saved. 
 
 
 
 
 
NOTE 
Setting the overwrite mode to ON deletes files, beginning with old files. If important data is to be 