Siemens CCMX1315-LP Benutzerhandbuch

Seite von 60
Configuration 
45 
Siemens Building Technologies
 
 
Fire Safety & Security Products 
 
01.2009
 
 
z
 
Scheduled Recording 
Determine the recording condition: STOP, all day, schedule 1 or schedule 2 from 
the recording schedule table for all days from Monday to Sunday. 
 
z
 
Recording by Alarm 
Configure "Alarm input setting" first. 
Then select the recording format: 
– 
Record source: choose JPEG or MPEG4 format 
– 
Recording frame 
Set the number of images to be recorded immediately after an alarm occurs.  
Images of the moment when an alarm occurs are not included. 
1, 2, 5, 10, 30 and 60 frames can be selected if JPEG format selected. No 
need for MPEG4 format 
– 
Recording cycle 
Set a time interval for alarm recording 1, 2, 5, 10, 30, 60, 90, 120 s can be 
selected for JPEG format, no need for MPEG4 format 
– 
Recording time: 
If MPEG4 is selected, please set the recording time to 2, 5, or 10 s. 
z
 
Recording by Motion 
Configure "Motion Detection Setting" first. 
All the other settings are same as recording by alarm as above. 
 
 
 
 
 
NOTE 
Make sure all NAS devices are ready on the network before activating this function.