Lucent Technologies 8.2 Benutzerhandbuch

Seite von 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
674
Feature-Related System Parameters 
17
is ready. The delay commences when the first group of digits has been outpulsed. 
Only appears if Vectoring (Basic) on the System-Parameters Customer-Options 
screen is 
y
.
Converse Signaling Tone/Pause
Only appears if Vectoring (Basic) and DTMF on the System-Parameters 
Customer-Options screen are 
y
. In the Signaling Tone field, enter the length in 
milliseconds of the digit tone for digits being passed to the CONVERSANT. In 
the Pause field, enter the length in milliseconds of the delay between digits being 
passed. The optimum timers for the CONVERSANT are a 100 msec tone and 70 
msec pause.
Prompting Timeout (secs)
Enter the number of seconds before the Collect Digits command times out for 
callers using rotary dialing. Only appears if Vectoring (Prompting) on the 
System-Parameters Customer-Options screen is 
y
.
Valid entries
Usage
0
 to 
9
Number of seconds for the delay.
Valid entries
Usage
40
 to 
2550
 (in 
increments of 
10). 
Values entered in the Tone/Pause fields are rounded up or 
down depending upon the type of circuit pack used to outpulse 
the digits.
TN742B or later suffix analog board 
 
Tone and pause 
round up or down to the nearest 25 msecs. For example a 
130 msec tone rounds down to 125 msecs, a 70 msec 
pause rounds up to 75 msec for a total of 200 msecs per 
tone.
TN464F, TN767E or later suffix DS1 boards
 — Tone and 
pause round up to the nearest 20 msecs. For example a 130 
msec tone rounds up to 140 msecs, a 70 msec pause 
rounds up to 80 msecs for a total of 220 msecs per tone.
If a circuit pack has been used for end-to-end signalling to the 
CONVERSANT, and has then been used to send digits to a 
different destination, the CONVERSANT timers may stay in 
effect. To reset your timers to the system default, pull and 
reseat the circuit pack.
100
 
Valid entries
Usage
4
 to 
10