Lucent Technologies Release 7 Benutzerhandbuch
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-136
ASAI-PT
9
Error Log Entries and Test to Clear Values
Notes:
a. This error occurs when the Level 1 Status Inquiry fails or when the BRI
circuit pack detects that Level 1 has been deactivated on the port. The
Aux Data
field contains one of the following values:
Refer to the repair procedures for Test #621.
b. The circuit pack is having problems transmitting data to the Packet Bus,
thus affecting the conveyance of signalling information over D-channel.
This error occurs when the Packet Bus transmit FIFO buffer overflows. This
condition probably indicates a hardware problem as well. The ASAI-PORT
alarm level is MAJOR with aux data 0. Use troubleshooting procedures for
both on-board hardware problems and potential off-board Packet Bus
problems.
This error occurs when the Packet Bus transmit FIFO buffer overflows. This
condition probably indicates a hardware problem as well. The ASAI-PORT
alarm level is MAJOR with aux data 0. Use troubleshooting procedures for
both on-board hardware problems and potential off-board Packet Bus
problems.
Table 9-53.
ASAI-PT Port Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
ASAI-PORT
ASAI-PORT
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1 (a)
(a)
Level 1 Status
Inquiry (#621)
Inquiry (#621)
MAJ
2
2.
Major and Minor alarms may be downgraded to warning alarms based on the value used in the set
options command.
options command.
OFF
test port UUCSSpp sh r 2
513 (b)
0
none
(b)
ON
1537 (c)
46210
CRC Error
Counter (#623)
Counter (#623)
MAJ
2
OFF
3841 (d)
46208
None
3844 (e)
46223
None
3845 (f)
46211
None
3846 (g)
TEI
None
Continued on next page
Blank
This indicates that the Level 1 Status Inquiry failed.
32773
This is a message from the ASAI-Line circuit pack indicating
Level 1 has been deactivated.
Level 1 has been deactivated.