Lucent Technologies Release 6 Benutzerhandbuch
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install Telecommunications Cabling
Page 2-23
Cable Installation
2
Connect Trunk Pairs to Cabinet Using Jumper
Wires To Establish 3-Pair Modularity
Wires To Establish 3-Pair Modularity
Figure 2-13 on page 2-23
Figure 2-14 on page 2-24
show trunk pairs
connected to the cabinet with jumper wires to establish 3-pair modularity.
Figure 2-13.
3-Pair Modularity for Trunk Pairs for 1-Pair Trunks
To connect the trunk pairs to the purple field:
1. Connect B25A cables between the network interface and the sneak fuse
panels. See
Figure 2-13
.
2. Connect A25D/B25A cables from the sneak fuse panels to the 110-type
terminal block-type connecting block connectors in the green field.
3. Connect 1-pair patch cords/jumper wires from each 110-type terminal
block row in the green field to the 110-type terminal block rows in the
purple field for 1-pair Central Office (CO) trunks or in
purple field for 1-pair Central Office (CO) trunks or in
Figure 2-14 on page
2-24
for 3-pair tie trunks.