Page 6-21
6.10 GPS/SBAS Antenna Cable Overbraid
The following removal and replacement steps are provided as guidance for replacing the cable overbraid 
assembly. See Figure 6-12.
Removal
1. Gain access to the GPS/SBAS antenna cable.
2. Disconnect the overbraid terminal lug from the shield block.
3. Disconnect the GPS coaxial cable connector at the GTN backplate.
4. Gain access to the GPS antenna and disconnect the antenna end of the coaxial cable.
5. Refer to the wire routing diagram and remove the entire cable assembly from the aircraft.
6. Remove the two visible electrical tie down connectors.
7. Unfold the overbraid that is doubled over and remove the remaining tie down connector.
8. Remove the antenna cable from the overbraid and visually inspect the cable insulation for damage.
Replacement
NOTE
Note: The length of overbraid required for replacement of the assembly will be the length 
of the GPS/SBAS antenna cable plus 6
". Refer to Figure 6-12 before beginning the 
reinstallation steps below.
1. If the antenna cable insulation shows signs of damage, replace the cable.
2. Test the GPS coaxial cable for continuity. Replace the cable if it fails the continuity test.
3. Slide the new overbraid over the entire length of the GPS/SBAS antenna cable.
4. Roll back approximately 1.5" of the overbraid end at the antenna end.
5. Leaving the rolled-back portion free, secure the antenna end of the overbraid around the
GPS/SBAS antenna connector with an electrical tie-down strap.
6. Fold the free overbraid ends back over the tie-down strap and secure them to the cable with two
additional tie-down straps.
7. Reinstall the cable in the aircraft and connect the cable to the GPS antenna.
8. At the GTN end of the overbraid, comb out a maximum of two" of braid, twist it, cut to length if
necessary, and terminate with a #10 terminal lug.
9. Connect the remaining end of the antenna cable to the GTN and terminal lug to the P1001 shield
block ground.