3.5 Setting Guard Zones and Alarms
The Pathfinder Plus Radar display allows you to set up one or two guard 
zones, using the ALARMS key. You can set up sector zones or 360° (circular) 
zones as shown in Figure 3-13.
Note: You can only view and control guard zones if you are using the Master 
display (that is, the display to which the scanner is connected).
            
Figure 3-13: Guard Zone Display
Guard zones are fixed with respect to the ship’s heading marker (SHM), 
moving as the SHM moves. They also move if you offset the centre, or if you 
change the range scale, so that the area you have marked is maintained.
The guard alarm sounds when a target enters a guard zone, exceeding the 
target density threshold within the zone; the alarm also sounds on a repeater 
display. The alarm sensitivity control allows you to set the threshold above 
which a new target will trigger an alarm, and also to turn the alarm on or off.
Note: A guard zone only operates when the whole zone is displayed on the 
screen, or could be displayed by offsetting the centre. In addition, a guard 
zone is inactive for 10 seconds after it is placed or re-sized, to avoid inappro-
priate alarms during positioning.
This section covers the following topics:
Placing a guard zone
Moving, reshaping or deleting a guard zone
Controlling guard zone alarms