3M ET 350 Benutzerhandbuch

Seite von 106
i
Product safety information
Intended Use
The 3M Dynapro
TM
 ET 350 monitor (specifically, monitor models ET 350R, ET 
350L2, and ET 350L3) is intended to provide touch screen functions when 
connected to a host computer in an industrial setting. The ET 350 monitor is not 
intended for use in hazardous locations.
Warning
To reduce the risk of fire or explosion which could result in serious 
personal injury or death:
„
Do not install or use this product in a hazardous location.
„
When using a flammable or combustible cleaning solution or fluid on or near 
the ET 350 monitor, refer to the cleaner manufacturer’s material safety data 
sheet and follow all instructions and recommendations.
To reduce the risk of fire or electric shock which could result in 
serious personal injury or death:
„
Follow all product and accessory installation instructions.
„
Any servicing or other procedures not described in this manual are to be 
performed only by 3M Touch Systems service personnel. 
„
For the ET 350R monitor in a Pollution Degree 3 environment, install the unit 
in an enclosure that is sealed to a NEMA 4X/IP66 standard. 
„
Install the ET 350 monitor close to the power source so the unit can be easily 
and quickly disconnected. For permanently connected equipment, a readily 
accessible disconnect device must be incorporated in the fixed wiring.
„
Engineer the installation of the ET 350 monitor to take into account the 
operating environment (e.g., thermal, shock/vibration factors).
„
Provide a clean, reliable grounding.
„
When connecting power with fixed field wiring for the ET 350L3 monitor and 
the ET 350R monitor, the power cable must be double insulated. A clear, 
flexible insulator (supplied) must cover  the portion of the cable that is not 
double insulated when connecting to a terminal strip connector.
„
Wiring installation should be done by a licensed journeyman electrician and 
must comply with federal and local electrical codes.
„
When replacing a fuse or other part, use a part of the type and rating specified 
by 3M Touch Systems.
„
Properly install the ET 350R monitor so that it is environmentally sealed to 
NEMA 4X/IP66 standard.
„
Properly install the ET 350R monitor with a NEMA 4X/IP66 gasket that is 
undamaged and  effective.
„
Do not use an ET 350 monitor that is not rated to NEMA 4X/IP66 in 
environments that require a NEMA 4X/IP66 seal.
„
Do not damage any ET 350 monitor gaskets.