3M 2250ME-iD Benutzerhandbuch

Seite von 52
 
16 
78-8130-6151-8-E
Note: In the ohms mode, the transmitter can detect voltage as well as ohms. If a low 
voltage is detected, the display will alternate between displaying ohms and volts. When 
displaying ohms, the flag over the 
Ω symbol will be visible. When displaying volts, the 
flag over the ‘V' will be visible. When the voltage magnitude is sufficient to impair the 
accuracy of the ohms measurement, only voltage will be displayed. If the voltage is 
AC, a sine wave will be visible on the display [T--4]. If a high AC voltage is detected, a 
rapid beeping tone will be heard.
3.  Press the Trace [T-3] repeatedly until the desired frequency appears on the display.
4.  Press Output [T-5] to select high output level for longer tracing distances or deep 
pipe/cable.
Dyna-Coupler Method
1.  Connect the Dyna-Coupler to the transmitter output jack [T-6] using the coupler 
cable (9011).
2.  Clamp the Dyna-Coupler around the cable or pipe, below any bonds, just before it 
enters the earth. The jaws of the coupler must fully close.
3.  Press Trace [T-3] to turn on the transmitter. Press again to select 8 KHz, 33 KHz or 
133 KHz.
Note: When using a Dyna-Coupler, always select high output level by pressing the 
output key [T-5] on the transmitter.