3M 2250ME-iD Benutzerhandbuch

Seite von 52
78-8130-6151-8-E 
21
4.  Press Clear All [SK] to delete all stored depth 
information.
 
− The operator may select the memory location 
to store the depth readings by pressing Mem 
Select
 [SK]. When the preferred location 
appears on the screen, press Save [SK]. The 
screen and memory location will populate 
with the current information.
 
− Each memory location can be reviewed by 
pressing Mem Select [SK].
5.  Press Locate [5] to return to Locate Mode.
Frequencies
Active
Active frequencies are trace signals supplied by a 3M
 Dynatel
 Transmitter 2200 
Series (577 Hz, 8 KHz, 33 KHz, or 133 KHz).
1.  Select the same frequency that the transmitter is generating;
2.  Press Locate [5]
3.  Press Cable/Pipe [SK]
4.  Press Freq [SK]
5.  Press ACTIVE [SK Toggle] until the desired frequency is displayed in the soft key 
command [9] (“Active” 577, 8K, 33K or 133K)
6.  Press Locate [5] to return to Locate mode.
Power
Power frequencies refer to 50 or 60 Hz signals, and their harmonics that can be traced 
without the use of a transmitter.
50: Best for general locating of passive power. 
50H (high harmonic): If the 50 choice appears to be responding slowly, or poorly, then 
50H is the second choice for locating of passive power.
50L (low harmonic): Third choice for passive power locating. May be used when 50 or 
50L is weak or erratic.
100 Hz: Used for locating rectified AC power signals, often found on pipelines using 
impressed current cathodic protection.
1.  Press Locate [5]
2.  Press Cable/Pipe [SK]
3.  Press Freq [SK]