3M 2250ME-iD Benutzerhandbuch

Seite von 52
78-8130-6151-8-E 
45
Cross:
Figure #2 Red clip to the crossed conductor of 
one pair; Black clip to the crossed conductor of 
the other pair.
Ground:
Figure #3 Red clip to the faulted conductor; 
Black clip to ground.
Split:
Figure #4 Red clip to Tip of Pair 1; Black clip 
to Ring of Pair 1.
Verify Split:
Figure #5 Red clip to good conductor of Pair 1; 
Black clip to split conductor of Pair 2
Cable Identification
Transmitter Setup
1.  Connect the 3M
 Dynatel
 Dyna-Coupler to the Transmitter output jack [T-6] using 
the coupler cable.
Note: Cable Identification requires two Dyna-Couplers: one at the Transmitter and 
one at the Receiver.
2.  Clamp the Dyna-Coupler around the cable or both the tip and ring of a pair. Make 
sure the jaws fully close.
3.  Press and hold [T-1] to perform a battery check.
4.  Press OHMS/FAULT/TONE [T-2] three times to set the transmitter to Tone mode.
 
− The indicator flag will light in the display [T-4] under the tone icon.
5.  Press OUTPUT [T-5] for high output level.
 
− The indicator flag will light in the display [T-4] above the output icon.
 
− The display [T-4] will alternately flash between 577 and 133K.