IMPORTANT: The battery for this unit is shipped dry. A package of battery acid (electrolyte) will have to be 
purchased separately. Allow sufficient time for charging and installing the battery before operating the rider.  
Pay close attention to the precautionary statements on the battery and in these instructions. You will also need 
an automotive type battery charger to activate the battery for use. 
 
STEP 1: Remove machine from the container. The 
battery will have to be charged and installed. 
STEP 2:  Remove battery from the battery compartment 
before charging. 
STEP 3: 
Place battery in a well ventilated area on a 
level non-concrete surface. 
 
WARNING 
The electrolyte (acid) produces a highly explosive gas. 
Keep all sparks, flame and fire away from area when 
charging battery or when handling electrolyte or 
battery. Electrolyte (acid) is a highly corrosive liquid. 
Wear eye protection. Wash affected areas immediately 
after having eye or skin contact with electrolyte (acid). 
Battery acid is corrosive. Rinse empty acid containers 
with water and mutilate before discarding. If acid is 
spilled on battery, bench, or clothing, etc., Flush with 
clear water and neutralize with baking soda. 
 
STEP 4: Remove battery cell caps. Fill cells as required 
with electrolyte (purchased separately) to proper level. 
Filling battery with electrolyte will bring the battery to 
80% charged state. 
 
 
 
WARNING 
DO NOT OVERFILL! 
 
 
 
STEP 5: With cell caps removed, connect battery 
charger to battery terminals; RED to positive (+) and 
BLACK to negative (-) terminal. 
STEP 6: Slow charge the battery at 2 amp for 2 hours 
to bring the battery to full charge. 
STEP 7: After charging, check level of electrolyte and 
add as needed to bring fluid to proper level. 
STEP 8: Reinstall cell caps. 
STEP 9: Install battery into power unit. 
 
 
 
 
 
 
 
STEP 10: Both bolts are already installed on both 
terminals. Connect positive (+) cable (red) first, from 
wiring harness to the positive terminal (+) on battery and 
secure with nut provided in hardware bag. Connect 
negative (-) cable (black) last, to negative terminal (-) on 
battery and secure with nut also provided. Apply a small 
amount of grease over terminals to prevent corrosion.  
See Figure 1. 
 
WARNING 
Shield the positive terminal with terminal cover 
located on battery harness. This prevents metal 
from touching the positive terminal, which could 
cause sparks. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
FIGURE 1 
 
STEP 11: Take the necessary precautions, when 
handling fuel. Fill the fuel tank with clean fuel. Check oil 
and add oil if needed as stated in Engine Owners 
Manual. Move fuel tank selector valve handle to the 
desired fuel tank.  
 
 
 
 
 
INSTRUCTION No. 7-5597 (I.R. 4/1/03) 
RED (POSITIVE) CABLE 
TERMINAL COVER MUST 
SHIELD POSITIVE 
TERMINAL AFTER 
INSTALLATION 
BLACK (NEGATIVE) CABLE