Section 4 - REPAIR & ADJUSTMENTS 
 
4.5. BATTERY SERVICE 
4.5.1.  NEW BATTERY PREPARATION 
1.  Remove battery from carton. 
2.  Place battery in a well ventilated area on a level 
non-concrete surface. 
3.  Remove battery cell caps. Fill cells as required 
with electrolyte (supplied with battery) to proper 
level. Filling battery with electrolyte will bring the 
battery to 80% charged state. 
4.  With cell caps removed, connect battery charger 
to battery terminals; RED to positive (+) and BLACK 
to negative (-) terminal. 
 
IMPORTANT: Never place anything in battery other than 
specified electrolyte. 
 
5.  Slow charge the battery at 1 amp for 2 hours to 
bring the battery to full charge. 
6.  After charging, check level of electrolyte and add as 
needed to bring to proper fluid level. 
7.  Reinstall cell caps. 
8.  Install battery into power unit. 
9.  Connect positive (+) cable (red) first, from wiring 
harness to the positive terminal (+) on battery using bolt 
and nut provided in hardware bag. Connect negative (-) 
cable (black) last, to negative terminal (-) on battery 
using bolt and nut. Apply a small amount of grease 
over terminals to prevent corrosion. 
 
WARNING 
DO NOT over fill battery with electrolyte. Shield the 
positive terminal with terminal cover located on 
battery harness. This prevents metal from touching 
the positive terminal, which could cause sparks. The 
electrolyte (acid) produces a highly explosive gas. 
Keep all sparks, flame and fire away from area when 
charging battery or when handling electrolyte or 
battery. Electrolyte (acid) is a highly corrosive liquid. 
Wear eye protection. Wash affected areas immediately 
after having eye or skin contact with electrolyte (acid). 
Battery acid is corrosive. Rinse empty acid containers 
with water and mutilate before discarding. If acid is 
spilled on battery, bench, or clothing, etc., Flush with 
clear water and neutralize with baking soda. Never 
attempt to charge battery while installed on the walk 
behind. Never use “BOOST” chargers on the battery. 
4.5.2. BATTERY SERVICE 
1.  Remove battery.  
2.  Place battery in a well ventilated area on a level 
surface. 
3.  Using distilled water, refill cells as required to 
cover cell plates. 
4.  With cell caps removed, connect battery charger 
to battery terminals.  Red to positive (+) terminal and 
black to negative (-) terminal. 
5.  Slow charge battery at 1 amp for 10 hours. 
6. If battery will not accept charge or is partially 
charged after 10 hours of charging at 1 amp, replace 
with new battery. 
 
4.5.3. BATTERY STORAGE 
If Walk Behind is to be stored out of season on its 
rear bumper, it is recommended the battery be 
removed, charged and stored. 
1.  Remove battery.  
2.  Perform battery service. 
3.  Bring battery to full charge, if required. 
4. Store battery in an area away from the Walk 
Behind on a wood surface. DO NOT STORE 
BATTERY ON A CONCRETE SURFACE. 
 
4.5.4. BATTERY TESTING 
There are two types of battery tests: Unloaded and 
Loaded. The unloaded test is the procedure that will 
be discussed. It’s the simplest and most commonly 
used. An unloaded test is made on a battery without 
discharging current. To perform unloaded testing, 
check charge condition using either a hydrometer or 
voltmeter. 
 
1.  Using a voltmeter, voltage readings appear 
instantly to show the state of charge. Remember to 
hook the positive lead to the battery’s positive 
terminal, and the negative lead to the negative 
terminal. 
2. A hydrometer measures the specific gravity of 
each cell. The specific gravity tells the degree of 
charge; generally, a specific gravity of about 1.265 to 
1.280 indicates full charge. A reading of 1.230 to 
1.260 indicates the battery should be charged. The 
chart on the next page shows the charge level as 
measured by syringe float hydrometer, digital 
voltmeter and five ball hydrometer. 
 
 
4.5.4. BATTERY 
TESTING 
 
Methods of Checking Battery Condition
State of Charge 
Syringe Hydrometer 
Digital Voltmeter 
Five Ball Hydrometer 
100% Charged w/ Sulfate Stop 
1.280 
12.80v 
Five Balls Floating 
100% Charged 
1.265 
12.60v 
Four Balls Floating 
75% Charged 
1.210 
12.40v 
Three Balls Floating 
50% Charged 
1.160 
12.10v 
Two Balls Floating 
25% Charged 
1.120 
11.90v 
One Ball Floating 
0% Charged 
Less than 1.100 
Less than 11.80v 
Zero Balls Floating