Dixon 700 Series Benutzerhandbuch

Seite von 21
MAINTENANCE INSTRUCTIONS
 
1. 
ENGINE: 
For complete maintenance and operating 
information for your engine, please refer to 
your engine operating and maintenance 
instructions furnished by the engine 
manufacturer and included in your Dixon 
Zero Turning Radius Mower information 
packet.
 
NOTE: Air intake screen must be kept 
clean. If plugged, engine may be seriously 
damaged by over heating.
 
2. 
BATTERY: 
 
Keep the electrolyte level above the plates 
in each cell by adding distilled water as it 
becomes necessary. Add water just before 
operating the mower to mix the water with 
the solution. Be careful not to overfill the 
battery - the electrolyte solution is corrosive 
and can cause damage to surrounding 
metal parts if it should spill. When taking 
the battery out of the mower for servicing, 
make sure to connect the cables to the 
battery exactly as they were prior to 
removal. Always disconnect the ground (-) 
wire first and always reconnect the ground 
(-) wire last.
 
Keep the battery clean. Remove the 
corrosion around the battery terminals by 
applying a solution of one part baking soda 
to four parts water. Coat all exposed 
terminal surfaces with a light layer of 
grease or petroleum jelly to prevent 
corrosion.
 
NOTE: 
3. 
TIRES: 
Correct tire pressure is essential for 
efficient operation of the mower. Check tire 
pressure as requested in the maintenance 
schedule. Inflate tires to the pressures 
listed below:
 
 
Lug nuts should be checked regularly for 
tightness.
 
~*. 
MOWER BLADES: 
Check sharpness of mower blades after 
every 10 hours of operation. To sharpen 
blades proceed as follows:
 
 
A. Remove bolt, lockwasher, and cup 
washer mounting blade on shaft. Remove 
blade.
 
B. Blades should be discarded when worn 
excessively.
 
C. Sharpen blades with a hand file, 
electric grinder or blade sharpener. Wear 
gloves and eye protection when 
sharpening. Grind blade at original 25 
degree bevel.
 
 
 
 
7
 
P-11408 (2/99) 
At temperatures below 32 degrees F 
(0 degrees C) the full charge state 
must be maintained to prevent cell 
electrolyte from freezing and causing 
permanent battery damage.