Cal Spas LTR20101000 Benutzerhandbuch

Seite von 60
2010 Portable Spa
LTR20101000, Rev. C
Operating 
Your Spa
www.calspas.com
14
Initial Start up
When first powered up, your spa will perform a self-
diagnostic  check  and  go  into  priming  mode.  The 
topside will display PR to indicate this. Priming mode 
will be active for less than five minutes.
Sometimes the pump fails to prime, especially when 
spa  owners  do  not  fill  their  spas  through  the  filter 
canister. You can avoid priming problems by following 
these steps during priming mode. 
Press the JETS 1 button to turn on the pump and 
1. 
let  it  run  for  10  seconds.  The  pump  should  be 
running in low speed.
Press the JETS 1 buttons again and let the pump 
2. 
run in high speed for 10 seconds.
Press  the  JETS  1  button  again  to  turn  off  the 
3. 
pump. The pump should be left in the off position 
for 10 to 15 seconds.
Repeat  steps  1  through  3  until  water  is  flowing 
4. 
through all the jets and all air is removed from the 
plumbing.
When the spa has finished priming, the heater will be 
activated and the water temperature will be maintained 
in standard mode.  The spa will heat to 100°F (37.5°C) 
at  start  up  until  the  set  temperature  is  changed  as 
described below.
Temperature Adjustment
(Range 80°F to 104°F, 26°C to 40°C)
The start-up temperature is set at 100°F (37.5°C). The 
last measured temperature is constantly displayed on 
the  control  panel.  Note  that  the  last  measured  spa 
temperature is displayed. The displayed temperature 
will be updated when the pump has been running for 
at least two minutes.
Press the “UP” or “DOWN” buttons once to display the 
set  temperature.  Each  time  either  button  is  pressed 
again, the set temperature will increase or decrease 
depending  on  which  button  is  pressed.  After  three 
seconds,  the  control  panel  will  automatically  display 
the last measured spa temperature.
Time
When time hasn’t been programmed, the “TIME” icon 
flashes. To set the time, press the “TIME” button and 
then  the  “MODE/PROG”  button.  Use  the  “UP”  and 
“DOWN” buttons to adjust time.  See the next page 
for more detailed instructions. 
Standard, Economy, Sleep, and Standby 
Modes
Mode/Prog: This button is used to switch between 
standard, economy, and sleep modes.
Press 
“MODE/PROG” 
to 
enter 
mode 
1. 
programming.
9800 Electronic Control Operation
These instructions will describe features and options that your particular spa may not be equipped with.