The Quick Reference Card provides a quick overview of your spa's main
functions and the operations accessible with your digital control pad.
Quick Reference Card
Troubleshooting
Pumps have started up for
one minute on several
occasions and "Filter Cycle"
icon is flashing.
Not a bug but a feature!
Our Smart Winter Mode
protects your system from
the cold by automatically
turning the pumps on for
one minute several times a
day to prevent water from
freezing in pipes.
Water temperature is
displayed.
Water temperature in the
spa has reached 112˚F
(44˚C).
Do not enter the water!
Allow water to cool down.
The system will reset au-
tomatically when water
reaches 109˚F (43˚C).
Call your dealer or service
supplier if problem persists.
3 flashing dots are dis-
played.
A problem has been de-
tected.
Do not enter the water!
Check and open water
valves. Clean filters if nec-
essary. Check water level.
Add water if needed.
Shut power off and power
your spa up again to reset
the system.
Call your dealer or service
supplier if problem persists.
The display is flashing.
A power failure has
occurred. Press any key
to reset the system, then
reprogram all desired
parameters.
Use Up or Down arrow key to regulate water 
temperature. The temperature setting will be 
displayed for 5 seconds to confirm your new 
selection.
 
The "Set Point" symbol indicates the
 
desired temperature, NOT the current
 
water temperature!
Water temperature can be adjusted by 1˚ in-
crements from 59 to 104˚F (15 to 40˚C).
Setting water temperature:
When water temperature is 1˚F (0.5˚C) 
lower than the Set Point, the heater will 
automatically turn on until water tempera-
ture reaches Set Point plus 1˚F (0.5˚C).
 
The "Heater" icon lights up when the
 
heater is on. It flashes when there is a
 
request for more heat but the heater
 
has not yet started.
Automatic water heater start:
Press and hold Light key for 5 seconds to 
display water temperature in either Fahr-
enheit (˚F) or Celsius (˚C).
Temperature display unit:
The display toggles every 5 seconds alternately 
showing the hourly time and the current water 
temperature.
Time & temperature display:
Press Pump 1 to turn Pump 1 on at low 
speed. Pressing a second time turns Pump 1 
to high speed. A third time turns Pump 1 off. 
When at high speed, a built-in timer turns 
pump off after 20 minutes and when at low 
speed after 2 hours, unless it has been 
manually deactivated.
 
The "Pump 1" icon lights up when
 
Pump 1 is on at high speed. It flashes
 
when Pump 1 is on at low speed.
Starting Pump 1:
Press Blower to turn blower on at high speed. 
Press a second time to turn blower to low 
speed. A third time turns blower off. A built-in 
timer turns blower off after 20 minutes, unless 
manually deactivated first. 
 
The "Blower" icon lights up when 
 
blower is on at high speed. It flashes 
 
when blower is on at low speed.
Starting the blower:
Starting Pump 2:
When blower or Pump 3 are not installed:
Press Pump 
2 once to turn Pump 2 on at low 
speed. Pressing a second time turns Pump 2 
to high speed. A third time turns pump off. A 
built-in timer turns pump off after 20 minutes, 
unless manually deactivated first.
 
The "Pump 2" icon lights up when
 
Pump 2 is on at high speed. It flashes
 
when Pump 2 is on at low speed.
When blower and Pump 3 are installed:
Press Pump 2 once to turn Pump 2 on at low 
speed. Pressing a second time turns Pump 3 
on and Pump 2 to high speed. A third time 
turns both pumps off. A built-in timer auto-
matically turns pumps off after 20 minutes, 
unless manually deactivated first. The
"Pump 2" icon lights up when Pump 2 and 
Pump 3 are on at high speed. It flashes
when Pump 2 is on at low speed.
The filter cycle is suspended if the water temperature raises more than 2˚F (1˚C) above Set 
Point . The "Filter" icon will blink (on 0.5 second, off 0.5 second, on 0.5 second, off 1.5 seconds).
MC-MP-DY2 SPA PACK
Press Pump 3 to turn Pump 3 on. Pressing a 
second time turns Pump 3 off. A built-in timer 
automatically turns pump off after 20 minutes, 
unless manually desactivated first.
Starting Pump 3:
Pressing Light key once turns light on at high 
intensity. Pressing a second time turns light to 
low intensity. A third time turns light off. A 
built-in timer turns light off after 2 hours, unless 
it has been manually deactivated.
 
The "Light" icon is displayed when light 
 
is on at high intensity. It flashes when   
 
light is on at low intensity.
Fiber Box Option: If spa has an optional fiber 
box only, pressing Light key turns fiber box 
(motor & light) on. Pressing again turns fiber 
box motor off but leaves light on. A third time 
turns both motor and light off. A built-in timer 
turns fiber box off after 2 hours, unless it has 
been manually deactivated. The "Light" icon is 
displayed when fiber box light is on. It flashes 
when fiber box motor and light are on at the 
same time.
Fiber Box & 12V light (via jumper)
Pressing Light key once turns fiber box (motor 
& light) and 12V light output on. Pressing again 
turns fiber box motor off but leaves lights on. A 
third time turns 12V light off and a fourth time 
shut fiber box light. The "Light" icon is displayed 
when fiber box motor is off and both lights on 
(or only the fiber box light). It flashes when 
fiber box (motor & light) and 12V light are on.
Turning the light on: