Cub Cadet 826 4x4 Benutzerhandbuch

Seite von 28
16
SECTION 8:  TROUBLE SHOOTING GUIDE
NOTE: For repairs beyond the minor adjustments listed above, please contact your local Cub Cadet dealer.
Trouble
Possible Cause(s)
Corrective Action
Engine fails to start 1.
Fuel tank empty, or stale fuel.
2.
Blocked fuel line.
3.
Choke not in the ON position
4.
Faulty spark plug.
5.
Safety key not in ignition 
switch on engine.
6.
Spark plug wire disconnected.
7.
Primer button not being used 
properly.
8.
Fuel shut-off valve closed.
1.
Fill tank with clean, fresh gasoline. Fuel becomes stale 
after thirty days.
2.
Clean the fuel line.
3.
Move switch to the ON position
4.
Clean, adjust gap or replace.
5.
Insert the key fully into the switch.
6.
Connect spark plug wire.
7.
Refer to the engine manual.
8.
Open fuel shut-off valve.
Engine runs erratic 1.
Unit running on CHOKE.
2.
Blocked fuel line or stale fuel.
3.
Water or dirt in the fuel 
system.
1.
Move the choke lever to OFF position.
2.
Clean the fuel line; fill the tank with clean, fresh gasoline. 
3.
Drain the fuel tank and carburetor. Refill with fresh fuel.
Loss of power
1.
Spark plug wire loose.
2.
Gas cap vent hole plugged.
1.
Connect and tighten spark plug wire.
2.
Remove ice and snow from gas cap. Be certain vent hole 
is clear.
Excessive 
vibration
1.
Loose parts or damaged 
auger.
1.
Stop the engine immediately and disconnect the spark 
plug wire. Tighten all bolts and nuts. If vibration continues, 
have the unit serviced by an authorized service dealer.
Unit fails 
to propel itself
1.
Traction control cable in need 
of adjustment.
2.
Drive belt loose or damaged.
1.
Adjust traction control cable. Refer to Making Adjustments 
Section.
2.
Replace drive belt. Refer to the Service Section.
Unit fails 
to discharge snow
1.
Discharge chute clogged.
2.
Foreign object lodged in 
auger.
3.
Auger control cable in need of 
adjustment.
4.
Auger belt loose or damaged.
5.
Shear bolt sheared.
1.
Stop engine  and disconnect spark plug wire. Clean 
discharge chute and inside of auger housing.
2.
Stop engine immediately and disconnect spark plug wire. 
Remove object from auger.
3.
Adjust  auger control cable. Refer to the Making 
Adjustments Section.
4.
Refer to Service Section.
5.
Replace shear bolt.
Electric chute  fails 
to turn
1.
Loose electrical connections.
2.
Blown Fuse.
1.
Make sure all connections are tight and fully installed.
2.
Replace with new 5 amps  fuse. (Fuse is located under 
handle panel near switch connector.)
Electric chute  
turns in opposite 
direction of the 
switch
1.
Switch connector installed 
backwards
1.
Unplug the switch connector under the handle panel. Turn 
connector 180° and reconnect.
Heated grips are 
not creating heat
1.
Loose electrical connections.
2.
Blown fuse.
3.
Faulty  heated handles grip. 
1.
Under the handle panel, check connections from the 
handles to the wiring harness.
2.
Replace with new 5 amps  fuse under the handle panel 
near crank switch connector.
3.
Have the grips checked at an authorized service dealer.
NOTE:  If one heated handles grip fails, both grips will not 
function.