Maintenance
 
To Replace Antifriction Bearings 
1.  Remove bolts holding end caps to housings. 
2.  Remove bolts holding bearing housings to yoke. 
3.  Remove bearing housings. 
4.  Remove the bearing with a puller. See Figure 6. 
5.  Check shaft and housing diameter for proper size 
with micrometer. 
6.  Heat the new bearing in an oven (200°F).  While 
it is hot, slide the bearing onto shaft – make 
certain that the inner race makes a firm even 
contact with shaft shoulder. Do not subject 
bearing to impact. 
7.  Let bearing cool - pack bearing caps with the 
proper grease. 
8.  Reassemble end caps and housings. 
 
The amount of grease to be used when repacking a 
bearing after cleaning or replacement is shown in the 
table below: 
 
Grease Quantity* 
(End Caps) 
Type 
Bearing 
Operating 
Bearing 
(Shaft) 
Outer Inner 
Deep Groove 
Ball 
Horizontal 
2/3 Full 
1/3 Full 
Roller 
Horizontal 
1/3 Full 
1/3 Full 
*
Pack all open bearings full between balls or roller but remove 
excess grease on outside of retainers.
 
 
 
Figure 3.  Ball Bearing Construction 
500, 580 & SH400 Frames 
 
 
 
 
 
Figure 4.  Ball Bearing Construction 
880 & SH450 Frames 
 
 
 
 
Figure 5.  Ball Bearing Construction 
SH560 Frame 
 
 
NOTE
 
1. 
For best results, seal should be positioned 
flush with outer-most bearing housing 
surface.  (Some frame sizes have shaft seal 
on only one end of the motor) 
 
 
 
 
 
 
Shaft Seal
See NOTE box; 
1.) is for CGZ, CZ 
& 1LA4