Sony HVR-Z7E/Z7P Benutzerhandbuch

Seite von 146
31
R
e
co
rd
in
g/
Pl
ay
bac
k
z
Tips
• While recording a bright subject, diffraction 
may occur if you close the aperture further 
down, resulting in a fuzzy focus (this is a 
common phenomenon with video cameras). The 
ND filter D suppresses this phenomenon and 
gives better recording results.
You can adjust the gain manually when you 
do not want to use the AGC (automatic gain 
control).
1
Set the AUTO/MANUAL switch F to 
MANUAL during recording or standby.
2
Set the gain switch H to H, M or L. 
The gain value set for the selected gain 
switch position appears on the screen. 
You can set the gain value for each gain 
switch position from [GAIN SETUP] of 
the 
 (CAMERA SET) menu 
To adjust the gain automatically
Press the GAIN button I, or set the 
AUTO/MANUAL switch F to AUTO.
b
Notes
• When you set AUTO/MANUAL switch F to 
AUTO, other manually adjusted items (iris, 
shutter speed, white balance) also become 
automatic.
You can manually adjust and fix the shutter 
speed. You can make a moving subject look 
still or emphasize the movement of a 
moving subject by adjusting the shutter 
speed.
1
During recording or standby, set 
AUTO/MANUAL switch F to 
MANUAL.
2
Press the SHUTTER SPEED button E.
3
Change the shutter speed displayed on 
the screen by turning the SEL/PUSH 
EXEC dial G. 
You can adjust the shutter speed in a 
range of 1/3 second through 1/10000 
second or the extended clear scan 
(
).
The denominator of the set shutter speed 
appears on the screen. For example, 
[100] appears on the screen when you 
set the shutter speed to 1/100 second. 
The larger the value on the screen, the 
faster the shutter speed.
4
Press the SEL/PUSH EXEC dial G to 
lock the shutter speed.
To readjust the shutter speed, do steps 
2
 to 4.
z
Tips
• When recording a subject such as a monitor 
screen, set the shutter speed in the extended 
clear scan  (
) range in order to obtain 
images with no horizontal bands of noise. You 
can set the shutter speed for the extended clear 
scan from [ECS FREQ.] in the 
 (CAMERA SET) menu (p. 71).
To adjust the shutter speed 
automatically
Press the SHUTTER SPEED button E 
twice, or set the AUTO/MANUAL switch 
F to AUTO.
b
Notes
• When you set the AUTO/MANUAL switch F 
to AUTO, other manually adjusted items (iris, 
gain, white balance) also become automatic.
z
Tips
• It is difficult to focus automatically at a lower 
shutter speed. Manual focusing with your 
camcorder attached to a tripod is recommended.
• The picture may flicker or change colors under 
fluorescent lamps, sodium lamps, or mercury 
lamps. You can reduce flickering by setting the 
shutter speed to an appropriate frequency in the 
extended clear scan (
) range 
([ECS FREQ.] p. 71).
Adjusting the gain
Adjusting the shutter speed
Continued 
,