Sampling procedure
 
1.
 
Press [SAMPLING/RESAMPLING] to access the 
Sampling Menu screen.
 
fig.5-01
 
The upper part of the screen will show the amount of free 
memory. If the free memory reaches 0%, no further sampling is 
possible.
 
2.
 
Press [F1 (Sampling)]–[F5 (Solo)] to select the 
sampling mode. The sampling-standby screen will 
appear.
 
(Example) Standby screen for Sampling
 
fig.5-02
 
3.
 
Make the settings for things such as the input source 
of the sound to be sampled, and triggering.
 
Function buttons
 
Parameters
 
[F1 (Sampling)]
Sample a sound from an external input source.
* Operating the velocity pads or D Beam con-
trollers will not play the internal sound gen-
erator.
[F2 (Re-Sampling)] Resample the sound of the internal sound gen-
erator.
* The sound of the external input will not be 
heard.
[F3 (Mix)]
(Mix sampling)
Sample the combined sounds of the internal 
sound generator and an external input source.
[F4 (Auto Divide)]
(Auto divide sam-
pling)
Sample an extended source, and automatically 
divide it into several samples at silent regions.
* Operating the velocity pads or D Beam con-
trollers will not play the internal sound gen-
erator.
[F5 (Solo)]
(Solo sampling)
While playing the internal sound generator as 
usual, sample only the sound from the external 
input.
* Effects cannot be applied to the external in-
put sound.
[F6 (Cancel)]
Return to the previous screen.
 
[F1 (Input Setting)]
[F2 (Auto Trig)]
(Auto Trigger)
If this is on, sampling will begin automati-
cally when the input sound is detected. 
[F3 (Trim Sw)]
If this is turned on, the Start point and End 
point settings (p. 115) will be automatically 
adjusted after sampling is performed, so 
any silent portions at the beginning or end 
of the sampled sound are excluded.
[F4 (BPM/Click)]
Set the tempo, and turn the metronome on/
off (p. 25).
 
Parameter
Range
Explanation
 
Input Select
LINE IN L/R, 
LINE IN L, 
DIGITAL(OPT), 
DIGITAL(CO-AX), 
MICROPHONE
Input source to be sampled
 
LINE IN L/R:
 
 INPUT 
jacks L/R (stereo)
 
LINE IN L:
 
 INPUT jack L 
(mono)
 
DIGITAL(OPT):
 
 Digital 
input (optical)
 
DIGITAL(CO-AX):
 
 Digi-
tal input (coaxial)
 
MICROPHONE:
 
 INPUT 
jack L (mono, mic level)
* This cannot be set when 
resampling.
Stereo 
Switch
MONO, STEREO
Stereo/mono setting for 
sampling
 
MONO:
 
 The sound will 
be sampled as one wave. 
If the sound is stereo, the 
left and right signals will 
be mixed.
 
STEREO:
 
 The sound 
will be sampled as two 
waves, L and R.
* Mono sampling uses 
half as much memory 
space.
Pre Sample 
Time
0–1000 ms
The length of sound pre-
ceding the moment at 
which sampling was man-
ually or automatically initi-
ated that will be captured 
in the sample
This lets you prevent the 
attack portion of the 
sound from being omit-
ted from the sample.
Stop Trigger
MANUAL, BEAT, 
TIME
How sampling will end
 
MANUAL:
 
 Continue 
sampling until you press 
[F5 (STOP)].
 
BEAT:
 
 Sample the spec-
ified number of beats at 
the current tempo 
(BPM).
 
TIME:
 
 Sample the speci-
fied length of time.
MC-909_Ref_e.book 112 ページ 2005年3月1日 火曜日 午後3時29分