Promise Technology 15110 Benutzerhandbuch

Seite von 264
Chapter 5: Management with the CLU
141
  Auto Rebuilding: On
Hot Spare Policy: Global
  Priority: High(RBLD), High(SYNC), High(Migration), High(RC), High(PDM)
--------------------------------------------------------------------------
Disk Array 1 Properties
  1. Create Logical Drive
  2. Delete Logical Drive
  3. Cache Policy
  4. Retry Count
  5. Enable/Disable SMART
  6. Name
  7. Priority
  8. Hot Spare
  9. Auto Rebuilding
  R. Return to Previous Menu
  Please enter your menu choice>8
5.
From this submenu, press 8 and Enter to access the Hot Spare Policy 
function.
Current hot spare policy:
 Global
 Change to Dedicated hot spare policy for LD 1(y/n)?>y
6.
Press Y and Enter to change the Hot Spare Policy to Dedicated. 
The physical drives selection appears.
  *********Physical Drives Selection*********
   ID
 Name
Capacity
  -------------------------------------------------------
   9 
WDC WD1200JD-00FYB0
120 GB
   11
ST380013AS
80 GB
   12
WDC WD1200JD-00FYB0
120 GB
  Enter Physical Drive ID to select.
  Press R to continue after you have finished
  selecting Physical Drive.
  Your input?>9
7.
From this submenu, press 9 and Enter to select the disk drive ID 9.
The previous screen reappears with disk drive ID 9 selected.
  *********Physical Drives Selection*********
   ID
 Name
 Capacity
  --------------------------------------------------------
 * 9 
WDC WD1200JD-00FYB0 120 GB