Zoom ST-224 Benutzerhandbuch

Seite von 76
23
Let's
Try
Out
Sampling
The ST-224 goes into the sampling standby mode, and the LED of
the [RECORD] key flashes. 
In this mode, sampling will start when the signal level exceeds a
certain threshold (trigger level). This is useful for example for
sampling drums or percussion sounds. 
While holding down the [SPECIAL] key, the currently selected trigger
level appears on the display. You can use the [-] and [+] keys to
change the trigger level. The following settings are available. 
• ArMoFF (default setting) 
Sampling starts immediately when [RECORD] key is pressed (auto
recording mode is off). 
• ArM 1 - ArM 3 
Auto recording mode is on. Higher figures mean a higher trigger
level. 
In this mode, sampling will stop automatically after a certain interval
(called the auto sampling time) has elapsed. This is useful for
example for sampling guitar phrases that you play yourself. 
While holding down the [PLAY/STOP] key, the currently selected auto
sampling time appears on the display. (The default setting is oFF.) 
Besides the manual sampling procedure using the [RECORD] key as described above, the ST-224 also
allows auto sampling where the start and stop of sampling is controlled automatically. There are two auto
sampling modes: the auto recording mode where sampling starts automatically when the signal level
exceeds a certain threshold, and the auto stop mode where sampling stops automatically after a preset
interval. 
BANK
SONG
PAD
1
FUNCTION
PAD ASSIGN CAPACITY
ERASE OPTIMIZE
PLAY/STOP
RECORD
RE-SAMPLE
GRADE
MONO
STEREO
SAMPLING
EDIT 2
VOLUME/BASS
EXCITER
TREMOLO
AUTO PAN
LO-FI EFFECT
EXTREME EQ
COMPRESSOR
RESONANCE
HIGH-PASS
LOW-PASS
DISTORTION
RING MODULATOR
PITCH SHIFTER
DIMENSION
CHORUS
PHASER
FLANGER
STEP CRY
DELAY
REVERB
TIME STRETCH
SCRATCH
EFFECT
ON/OFF
PAD ENABLE
A
B
EFFECT SYNC
EDIT 1
4
OFFSET
6
PANNING
TUNING
5
PRE COUNT
END POINT
3
TIME SIG
START POINT
1
BAR LENGTH
LEVEL
7
CLICK VOLUME
REVERSE
COPY
DELETE
BACKUP
EXIT
SPECIAL
LOAD
SAVE INTERNAL/DATA CARD
+
AUTO SYNC
PLAYLIST
TAP
BPM
SONG
PLAY/STOP
REC
BPM/VALUE
MEASURE
SAMPLE/SONG
BEAT
Connect the sound source and adjust the input level. Then press the [RECORD] key.
1
STEP
Select the desired sampling grade and the mono/stereo setting. 
2
STEP
To perform sampling in auto recording mode, hold down the [SPECIAL] key.
3
STEP
To perform auto stop sampling, hold down the [PLAY/STOP] key.
4
STEP
(2) Auto Sampling
RECORD