page 22 — wm63-series mixer • operaTion and parTs manual — rev. #0 (09/27/12) 
start-up
This section is intended to assist the operator with the initial 
start-up of the unit. It is extremely important that 
this section be read carefully before attempting 
to use the mixer in the field. 
do noT use your 
mixer until this section is thoroughly understood.
The following steps outline the procedure for starting the 
engine. 
1.  Move  the  fuel  shut-off  lever  (Figure  14)  to  the  ON 
position.
Figure 14. Fuel Shut-Off Lever
2.  To start a cold engine, move the choke lever (Figure 
15) to the CLOSED position.
Figure 15. Choke Lever
  warning
Failure to understand the operation of the mixer could 
result in severe damage to the mixer or personal injury. 
See Figure 4 for the location of any control referenced 
in this manual.
  CauTion
never operate the mixer in a confined 
area or enclosed area structure that does 
not provide ample free flow of air.
3.  Move the throttle lever (Figure 16) away from the slow 
position, about 1/3 of the way toward the fast position.
Figure 16. Throttle Lever
4.  Turn the engine switch (Figure 17) to the ON position.
Figure 17. Engine On/Off Switch
5.  The main start/stop switch located on the engine cover  
(Figure 18) is used to start and stop the engine. Pull 
this switch outward to start the engine.
Figure 18. Start/Stop Switch
PULL OUT