Multiquip WM63H8 Benutzerhandbuch

Seite von 60
page 28 — wm63-series mixer • operaTion and parTs manual — rev. #0 (09/27/12) 
Maintenance (Mixer)
drum Head seals
There is 1 set of drum head seals (Figure 29) that will 
require  lubrication.  Lubricate  the  grease  fitting  for  each 
drum seal every 40 hours of operation using any grade 
lithium base grease. Apply grease until visible inside of 
mixing drum (over grease). This will purge seal system of 
contamination.
Figure 29. Grease Fittings (Drum Head Seals)
drum Bearing BraCkeT luBriCaTion
There is 1 set of drum bearing brackets (Figure 30) that 
will require lubrication.  These brackets are intended to 
make the drum rotate freely. Lubricate the grease fitting 
for each drum bearing bracket every month or when the 
drum  becomes  difficult  to  position  using  multi-purpose 
grade grease.
Figure 30. Grease Fittings (Dumping 
Mechanism)
Ball soCkeT and Clamp FaCe mainTenanCe
1.  If the towing vehicle is equipped with a ball socket, 
smear socket periodically with multi-purpose grease. 
This will keep the ball socket well lubricated.
2.  Periodically oil pivot points and clamp face surfaces of 
coupler with SAE 30 WT. motor oil.
3.  When parking or storing your mixer. Keep the coupler 
off the ground so dirt will not build up in the ball socket.
CounTersHaFT Bearing luBriCaTion
There is 1 set of countershaft bearings (Figure 31) that 
will require lubrication. Lubricate the grease fitting for each   
countershaft bearing every 40 hours of operation using any 
grade lithium base grease.
DRUM BEARING
BRACKET
  CauTion
Failure to lubricate the drum bearing grease fittings 
periodically  will  cause  the  dumping  mechanism  to 
stiffen, making the mixing drum hard to dump.