Calculating the Power Consumption
The following facts are important for the choice of power supply units for 52/RX Mixing Consoles.
·
Use two 52-5048 power supply units for larger mixers with redundancy option inside the 52-5081 or 52-5083 power
supply frames. The maximum power consumption in total is 200W.
·
Use two 52-5048 power supply units for several smaller mixers with redundancy option inside the 52-5081 or 52-
5083 power supply frames. The maximum power consumption in total is 200W.
·
You may also use two 52-5047 power supply units for smaller mixers with redundancy option inside the 52-5081 or
52-5083 power supply frames. The maximum power consumption in total is 100W.
·
Use  the  52-4048  desktop  power  supply  for  smaller  mixers  in  non  redundant  installations.  The  maximum  power
consumption in total is 100W.
·
PoE switches are not included in all 52/RX fader and control modules or table installation frames.
·
Use  52-4080  PoE  switches  mounted  close  to  the  console  or  52-5088  PoE  switches  inside  the  52-5083  power  supply
frames.
Important
There are two 48V connectors on each 52-4080 PoE switch. At revision A of the
PoE switch (52-4080A), the second speakon connector can be used to chain to
another 52-4080. Do not connect two power supplies to a 52-4080A to achieve
redundant power supply! There is no diode included in the 52-4080A!
Revision  B  of  the  PoE  switch  (52-4080B)  provides  the  option  to  connect  a
redundant  power  supply  to  the  module.  Nevertheless,  in  revision  B  it  is  still
possible to connect  through  the  PoE  switch  to  another  PoE  switch.  Please  take
care about the internal wiring!