Upgrading an Existing G700 with an S8300 — R1.x to R2.0
Upgrade the S8300
Upgrade the S8300
228
Installation and Upgrades for G700 and S8300
December 2003
Install the pre-upgrade update (patch)
1
Use Telnet to access the media server.
a
Click
Start > Run
to open the Run dialog box.
b
Type
telnet 192.11.13.6
and press
Enter
.
c
Log in as craft.
2
Type
cd /var/home/ftp
and press
Enter
to access the ftp directory.
3
At the prompt, type
ls -ltr
and press
Enter
to list files in the ftp directory.
The S8300 displays a list of files in the ftp directory.
4
Verify that the directory contains the *.tar.gz file you have uploaded.
5
Type
sudo patch_install
patch.tar.gz
, where
patch
is the release or issue number of the update
file. (For example,
03.0.526.5-1003.tar.gz
). Press
Enter
.
6
Type
patch_show
again and press
Enter
to list Communication Manager files to verify the new
software file was installed.
7
Type
sudo patch_apply
patch
, where
patch
is the release or issue number of the update file.
(For example,
03.0.526.5-1003
. Do not use the *.tar.gz extension at the end of the file name).
Press
Enter
.
The media server goes through a software reset system 4. You must wait until the restart/reset has
completed before entering additional commands. The reset should take 1–2 minutes (or longer if
messaging is enabled).
completed before entering additional commands. The reset should take 1–2 minutes (or longer if
messaging is enabled).
8
Type
patch_show
again and press
Enter
to list Communication Manager files to verify the new
software file was applied.
9
Before proceeding, type
statapp -c
to view the status of the processes. Make sure everything
except
dupmgr
shows UP.
Communication Manger
should show
65/65 UP
or, if IA770 is installed,
67/67 UP
. To stop the continual refresh of the
statapp
command, type
Ctrl-C
.
NOTE:
The number of processes (65/65) may vary depending on the configuration. For a normal
state, the second number should not be greater than the first number. For example, the
numbers 64/65 UP would indicate that a process did not come up and should be
investigated before proceeding.
state, the second number should not be greater than the first number. For example, the
numbers 64/65 UP would indicate that a process did not come up and should be
investigated before proceeding.
10
Close the browser.