Agilent Technologies A.18.00 Benutzerhandbuch

Seite von 581
494
S:\agilent\8920\8920b\PRGGUIDE\BOOK\CHAPTERS\callproc.fb
 
Chapter 8, Programming the Call Processing Subsystem
CALL BIT Screen Message Field Descriptions
REG INC Message Fields
Figure 48
 REG INC Message Fields
T1T2
This field identifies the received message as an order confirmation, an order, or a called 
address message. 
2 binary characters required.
DCC
Digital color code field.
2 binary characters required.
ACT
Global Action Field.
4 binary characters required.