14.0  error Conditions/error Messages
Your spa has a self-diagnostic control system. The system will 
automatically display the following if a problem is detected.
14.1  summer logic
When the actual spa water temperature reaches 2 °F 
(1 °C) above the set temperature, the spa goes into 
“summer logic.” The 24-hour circulation pump will turn off 
automatically to avoid adding additional heat to the water, 
eventually creating an overheat condition. This setting is 
not user-programmable.
note: Summer logic does not take effect until the spa water temperature 
reaches 95 °F (35 °C). This condition is more likely in excessively hot 
weather. Remember, the spa’s ability to cool is directly affected by 
the ambient temperature. An excessively hot ambient temperature 
may prevent the spa from cooling down because it’s fully insulated 
construction is designed to retain heat and minimize operating costs.
14.2  panel Displays Col
Cool Condition - Temperature has dropped 20 °F (11 °C) 
below the current set temperature. Jets pump 1 and the 
heater have been activated to bring the temperature within 
15 °F (8 °C) of the set temperature. No corrective action is required!
note: This condition is common during first time fill ups or during refills 
since tap water is often very cold.
14.3  panel Displays ICe
Freeze Protection - A potential freeze condition has been  
detected. No action is required. Jets Pump 1 and heater 
will activate to circulate and warm water through the plumbing until spa is 
out of danger. See “Winterizing” (page 35).
14.4  panel Displays sn1
Open sensor (heater is disabled) or shorted sensor (spa 
is deactivated). The high-limit temperature sensor is not 
functioning. Contact your authorized Jacuzzi dealer or 
qualified service technician.
14.5  panel Displays sn2
Open or shorted sensor (heater disabled). The 
temperature sensor is not functioning. Contact your 
authorized Jacuzzi dealer or qualified service technician.