The V/f free-setting endpoint f7/V7 
parameters must stay within the more 
basic inverter limits in order for the 
specified free-setting characteristic 
curve to be achieved. For example, the 
inverter cannot output a higher voltage 
than the input voltage or the AVR 
setting voltage (Automatic Voltage 
Regulation), set by parameter A082. 
The graph to the right shows how the 
inverter input voltage would clip (limit) 
the characteristic curve if exceeded.
Sensorless Vector Control and, Sensorless Vector Control, 0Hz Domain – These advanced 
torque control algorithms improve the torque performance at very low speeds:
• Sensorless Vector Control – improved torque control at output frequencies down to 0.5 Hz
• Sensorless Vector Control, 0Hz Domain – improved torque control at output frequencies 
from 0 to 2.5 Hz.
These low-speed torque control algorithms must be tuned to match the characteristics of the 
particular motor connected to your inverter. Simply using the default motor parameters in the 
inverter will not work satisfactorily for these control methods. Chapter 4 discusses motor/
inverter size selection and how to set the motor parameters either manually or by using the 
built-in auto-tuning. Before using the sensorless vector control methods, please refer to 
NOTE: When the inverter is in SLV (sensorless vector) mode, use B083 to set the carrier 
frequency greater than 2.1 kHz for proper operation.
NOTE: You must disable sensorless vector operation when two or more motors are connected 
(parallel operation) to the inverter.
Vector Control with Encoder Feedback – This method of torque control uses an encoder as a 
motor shaft position sensor. Accurate position feedback allows the inverter to close the velocity 
loop and provide very accurate speed control, even with variations in motor loads. To use 
encoder feedback you will need to add an SJ–FB Encoder Feedback Card in the inverter’s 
expansion bay. Please refer to 
 in this manual or the SJ–FB 
manual for details.
The following table shows the methods of torque control selection.
Output voltage
Output
frequency
(even)
B101 to
 B113
(odd)
Voltage to output or AVR voltage
B100 to B112
V7
V6
0
f6
f7
Hz
“A” Function
Run 
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)
A041 Torque boost method 
selection
Two options:
00 Manual torque boost
01 Automatic torque boost
✘ ✘
00
00
00
>A041 V-Boost
Mode      MANUAL
A241 Torque boost method 
selection, 2nd motor
Two options (for 2nd 
motor):
00 Manual torque boost
01 Automatic torque boost
✘ ✘
00
00
00
>A241 2V-Boost
Mode      MANUAL