Ridgid R7130 Benutzerhandbuch

Seite von 18
15
MAINTENANCE
WARNING:
This tool should never be con nect ed to a power  
supply  when  you  are  performing  main te nance. 
Disconnecting  the  tool  will  pre vent  ac ci den tal 
starting that could cause  serious in ju ry.
BRUSH REPLACEMENT
See Figure 12.
The  drill  has  externally  accessible  brush  assemblies  that 
should be periodically checked for wear. 
To replace the brushes:
n
Unplug the drill.
n
Using a T10 torx screwdriver, remove the screw that holds 
the brush cap cover in place.
n
Remove the brush cap with a flat blade screwdriver. The 
brush assembly is spring loaded and will pop out when 
you remove the brush cap.
n
Remove the brush assembly (brush and spring). 
n
Check for wear. If worn, always replace in pairs. 
Do not 
replace one side without replacing the other.
n
Replace the old brush assembly with a new one.
n
Place the brush cap on the brush assembly and tighten 
with the flat blade screwdriver.
n
Place the brush cap cover on the brush assembly and 
tighten with the torx screwdriver.
WARNING:
When  servicing  use  only  iden ti cal  RIDGID 
replacement  parts.  Use  of  any  other  parts  may 
create a hazard or cause product damage.
WARNING:
Always wear safety goggles or safety glasses with 
side shields during power tool operation or when 
blowing  dust.  If  operation  is  dusty,  also  wear  a 
dust mask.
GENERAL MAINTENANCE
Avoid  using  solvents  when  cleaning  plastic  parts.  Most 
plastics are susceptible to damage from various types of 
commercial solvents and may be damaged by their use. Use 
clean cloths to remove dirt, dust, oil, grease, etc.
WARNING: 
Do  not  at  any  time  let  brake  fluids,  gasoline, 
petroleum-based products, penetrating oils, etc., 
come in contact with plastic parts. Chemicals can 
damage,  weaken  or  destroy  plastic  which  may 
result in serious personal injury.
Electric tools used on fiberglass material, wall board, spack-
 ling compounds, or plaster are subject to ac cel er at ed wear 
and possible premature failure be cause the fi ber glass chips 
and grindings are highly abrasive to bearings, brushes, com-
 mu ta tors, etc. Consequently, we do not recommended us ing 
this tool for extended work on these types of materials. How-
 ev er, if you do work with any of these materials, it is extremely 
important to clean the tool using com pressed air.
LUBRICATION
All of the bearings in this tool are lubricated with a sufficient 
amount of high grade lubricant for the life of the unit under 
normal operating conditions. Therefore, no further lu bri ca tion 
is required.
Fig. 12
BRUSH 
ASSEMBLY
BRUSH 
CAP
SCREW
BRUSH CAP 