Energizer E10HH Merkblatt

Seite von 1
Chemical System:
Zinc Air (ZnO
2
)
Tab Color:
Yellow
Designation:
IEC-PR70
Nominal Voltage:
1.4 Volts
Typical Capacity:
91 mAh (to 0.9 volts)
(Rated at 3k ohms at 21°C/65% RH)
Typical Weight:
0.32 grams
Typical Volume:
0.08 cubic centimeters 
Load
Cutoff
0.9V
(ohms)
(hours)
3,000
211
6,000
414
Typical Discharge Characteristics
Impedance vs. Depth of Discharge
Specifications
(millimeters)
Industry Standard Dimensions
Impedance 
(bottom view)
Impedance vs. Frequency
(top view)
 ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
16 Hours/Day
0.43
16 Hours/Day
0.22
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication. 
Specially designed for use in humid climatic conditions.
ENERGIZER E10HH
Zinc Air
(milliamperes)
at 1.3V 
Simulated Application Test
Schedule:
Typical Drains:
Typical Performance at 21°C & 50% RH
PRODUCT DATASHEET
0.8
0.9
1.0
1.1
1.2
1.3
1.4
0
50
100 150 200 250 300 350 400 450
Op
er
at
ing
 V
o
lt
ag
e
Service, Hours
Schedule: 16 hours/day
Typical Drain @ 1.3V:
0.43 & 0.22 milliamperes
Load: 3K & 6K ohms
3K
6K
0
5
10
15
20
25
30
35
0.1
1
10
100
1000
10000
100000
Im
pedan
ce (
o
h
m
s)
Frequency (Hz)
00% DoD
25% DoD
50% DoD
80% DoD
0
5
10
15
20
25
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Im
pedan
ce (
o
h
m
s)
Depth of Discharge
40 Hz
1K Hz
The total opposition that a battery offers to the flow of alternating 
current. Impedance is a combination of resistance and reactance.
The typical impedance of these cells on open circuit and during 
useful discharge varies from 5-20 ohms. This applies over a 
frequency range of 40-5,000 hertz at the current drains shown 
below. 
Asia Pacific Region
+852-31026623
3.18
3.00
1.35R
Typical
0.015
Typical Coining Depth
5.60
5.80
0.25
Minimum
3.30
3.60
Form No. EBC - 8953AP
Page 1 of 1