Grizzly G0441 Benutzerhandbuch

Seite von 56
-20-
Model G0440/G0441 (Mfg. Since 03/12)
5.  Place  the  intake  barrel  brace  in  position 
and mark the location of the mounting holes 
(shown in 
Figure 13) with a small pencil, nail, 
or push pin.
Figure 14. Using tape on wrench in tight spot.
6.  Remove  the  intake  barrel  you  temporar-
ily attached in 
Step 4, drill holes where you 
marked in 
Step 5, and loosely install the wall 
mount  brace  to  the  wall  with  the  remaining 
fasteners  from  the 
Wall Mounting proce-
dure.
7.  Use the (12) 
5
16
"-18 x 
3
4
" hex bolts and (12) 
5
16
"  flat  washers  to  re-install  the  intake  bar-
rel  to  the  housing  with  a  barrel  gasket  in 
between, as shown in 
Figure 12 on the previ-
ous page.
 
Note:  When installing the two bolts above 
the intake port, use duct tape on the bottom 
of your wrench to hold the bolts in place, as 
shown in 
Figure 14, to start the bolts easier.
Figure 13. Intake barrel brace positioned to 
mark the mounting holes.
Mounting 
Hole 
Locations
8.  Attach the cyclone funnel to the intake barrel 
with a barrel gasket between them, as shown 
in 
Figure 15, using (12) 
5
16
"-18 x 1" hex bolts, 
(24) 
5
16
"  flat  washers,  and  (12) 
5
16
"-18  hex 
nuts; also secure the wall mounting brace to 
the  lip  of  the  intake  barrel/funnel  assembly 
with the same hardware.
 
Note: At the places where you see 3 holes in 
a row, only use the center hole for this step. 
The two outside holes are only designed for 
use with the optional stand.
Figure 15. Cyclone funnel attached to intake 
barrel.
Barrel 
Gasket Here
9.  Tighten the wall mounting brace to the wall.
10.  Attach  the  cyclone  vacuum  tube  to  the 
cyclone funnel with (4) 
5
16
"-18 x 
3
4
" hex bolts 
and (4) 
5
16
" flat washers (see 
Figure 16).
Figure 16. Cyclone vacuum tube and hose 
attachment.