note: Always use an air line filter to remove moisture and oil vapor  
when spraying paint.
Location
Place  the  air  compressor  in  a  clean,  dry  and  well  ventilated  area 
at least 12" (30.5 cm) away from the wall or other obstructions that 
will  interfere  with  the  flow  of  air.  Keep  the  compressor  away  from
areas that have dirt and/or volatile fumes in the atmosphere. These 
impurities may clog the intake filter and valves, causing inefficient 
operation. 
The  air  compressor  pump  and  shroud  are  designed  to  allow  for 
proper  cooling.  The  ventilation  openings  on  the  compressor  are 
necessary to maintain proper operating temperature. Do not place 
rags or other containers on or near these openings.
Place  the  air  compressor  on  a  flat  surface  resting  on  the  rubber 
feet.
noISe ConSIDerAtIonS
Consult  local  officials  for  information  regarding  acceptable  noise 
levels in your area. To reduce excessive noise, use vibration mounts 
or silencers, relocate the unit or construct total enclosures or baffle 
walls. Contact a D
e
WALT service center.
eLeCtrICAL
Refer to all safety instructions before using unit. Observe extension 
cord  safety  instructions  if  necessary.  Always  move  the  On/Off 
switch (A)  to  the  OFF  position  before  removing  the  plug  from  the 
outlet.
trAnSPortInG
When transporting the compressor in a vehicle, trailer, etc., ensure 
that the tank is drained and the unit is secured. Use care when driv-
ing to avoid tipping the unit over in the vehicle. Damage can occur to 
the compressor or surrounding items if the compressor is tipped.
MoVInG
When moving the compressor, grasp the handle and carry the com-
pressor as close to the body as possible.
WARNING: Risk of unsafe operation. ensure proper footing and 
use caution when carrying compressor to avoid a loss of balance.
PrEPArAtIon For uSE
Pre-Start Checklist (Fig. 1)
 1.  Ensure the On/Off switch (A) is in the OFF position.
 2.  Plug the power cord into the correct branch circuit receptacle. See 
Voltage and Circuit Protection under Installation.
 3.  Ensure  air  tank  is  drained,  see 
Draining  Air  tank  under 
Maintenance. 
 4.  Ensure the drain valve (G) is closed. 
 5.  Ensure  safety  valve  (F)  is  functioning  properly,  see 
Checking 
Safety Valve under Maintenance.
 6.  Turn regulator knob (D) counterclockwise until fully closed. Ensure 
regulated pressure gauge reads 0 psi.
 7.  Visually inspect air hose, replace if needed.
 8.  Attach hose and accessories.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand 
when installing or disconnecting to prevent hose whip.
WARNING:  Risk  of  unsafe  operation.  Do  not  use  damaged  or 
worn accessories.
WARNING:  Risk  of  bursting.  Too  much  air  pressure  causes  a 
hazardous  risk  of  bursting.  Check  the  manufacturer’s  maximum
pressure rating for air tools and accessories. The regulator outlet 
pressure must never exceed the maximum pressure rating.