IMPORTANT: Make sure the electrical 
characteristics are the same on the motor 
nameplate and the power source, and make 
sure the circuit on which the jointer will be used 
is properly fused and that the wire size is 
correct. 
 
Converting from 230 Volt to 460 Volt 
(Three Phase Only) 
Consult the wiring diagram inside the starter box 
cover. A diagram is also included on pages 37-
38 of this manual. The Jointer must comply with 
all local and national codes after being wired. 
1.  Remove the starter box cover and adjust the 
dial on the relay (see Figure 10) as close as 
possible to the amperage of the Jointer 
motor at 460V, as listed on the motor plate. 
2.  Move the fuse (Figure 10) from the 230V 
slot to the 460V slot. 
3.  Re-connect the incoming leads to the motor 
for 460 volt operation, as shown in the 
wiring diagram. 
4.  If using a plug, install a proper UL/CSA 
listed plug suitable for 460 volt operation.  
Three-Phase Test Run 
On the three-phase unit, after wiring has been 
completed, you should check that the incoming 
leads have been connected properly: 
1.  Connect machine to power source and 
press the start button (make sure cutterhead 
is clear of all obstructions!). 
2.  The cutterhead should rotate clockwise as 
viewed from the front of the machine. If  the 
cutterhead rotation is incorrect, press the 
stop button and disconnect machine from 
power. 
 
3.  Switch any two of the three leads to the 
motor. 
Extension Cords 
Make sure your extension cord is in good 
condition. Always use a cord that is heavy 
enough to carry the current your product will 
draw; the cord rating must be suitable for the 
amperage listed on the machine’s motor plate. 
An undersize cord will cause a drop in line 
voltage resulting in loss of power and 
overheating. 
Use the chart in Figure 11 as a general guide in 
choosing the correct size cord. If in doubt, use 
the next heavier gauge. The smaller the gauge 
number, the heavier the cord. 
 
 
 
 
 
 
 
 
Figure 10 
 
 
 
 
 
 
 
Extension Cord Recommended Gauges (AWG) 
Extension Cord Length *  
Amps 
25 
feet 
50 
feet 
75 
feet 
100 
feet 
150 
feet 
200 
feet 
5  16 16 16 14 12 12 
to 
8  16 16 14 12 10 NR 
to 
12  14 14 12 10 NR NR 
12 
to 
15 12 12 10 10 NR NR 
15 to 20 
10 
10 
10 
NR 
NR 
NR 
21 
to 
30  10  NR NR NR NR NR 
*based on limiting the line voltage drop to 5V at 150% of the 
rated amperes. 
NR: Not Recommended. 
Figure 11