Lincoln Electric V205-T Benutzerhandbuch

Seite von 109
V205-T AC/DC
TROUBLESHOOTING & REPAIR
F-6
F-6
Observe Safety Guidelines
TROUBLESHOOTING GUIDE
detailed in the beginning of this manual.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed.  Call
1-800-833-9353(WELD).
FUNCTION PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
FUNCTION PROBLEMS
Error code “E20”, “E24”, or “E25”
is flashing on the digital display.
1.  Any one of these codes indi-
cates a memory error.
1.  The Control/Display Board is
faulty.  Replace.
No High Frequency when the torch
trigger is pulled and the machine is
in the TIG mode.
1.  Make sure the HF is in the
1. Check fuse F2 on the Bus
Board.  
2.  
4. The HF board may be faulty.
Replace.
Error code “E14” is flashing of the
digital display
1.  This is an indication that the
output inductance is too high.
1. Check for excessive welding
cable length.
2. The Main IGBT Inverter Board
may be faulty.
3. The Superimposition Board may
be faulty.
4. The Control/Display Board may
be faulty.
The machine functions normally
except the cooling fan does not
operate.  
1. Check for obstructions that
could prevent the fan from turn-
ing.
1. Check the fan fuse F3 located on
the Bus Board   Replace if faulty.
3.  The Main IGBT Inverter Board