CAUTION
TROUBLESHOOTING AND REPAIR
F-11
F-11
VRTEX 
TM
360
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3878.
FUNCTION PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
The  VRTEX
TM
360  does  not
function correctly in the GMAW
mode.  It works correctly in the VR
SMAW (stick) mode.
Make  sure  the  VR  GMAW
Device is connected properly.
Make sure the correct welding
procedures are set.
Check  for  loose  or  faulty
connections,  at  the  ribbon
cable, between the USB Digital
I/O Module and the terminal
block interface.  Also check
between  the  terminal  block
interface and the Relay Board.
See the wiring diagram
Check the VR GMAW trigger
connector (audio type) for a
loose or faulty connection.
Perform the Interface Digital
Module IO Test.
The Relay PC Board may be
faulty.
The VR GMAW Device may be
faulty.
There is jitter or shaking in the
Helmet display and Monitor.
Make sure there is not any TIG
welding  or  high  frequency
interference in the immediate
area.
Check  for  loose  or  faulty
connections  between  the
Helmet/Monitor  and  the
VRTEX
TM
360 machine.   See
the wiring diagram.
The CPU constantly looses the
current time and date.   At initial
boot-up  the  monitor  reads
“CMOS” battery failed.
The internal battery in the CPU
has  failed.    A  qualified
technician needs to address this
problem.
Perform  the  CPU  Removal
Procedure
.      Replace  the
internal battery in the CPU.
(KTS CR2032)
As viewed through the helmet and
the  monitor,  the  entire  stand
assembly appears in the middle of
the screen and the environment
does not move.
N/A
Check all cables and leads to
the  Polhemus    Interface
Module  for  loose  or  faulty
connections.
Perform  the  Polhemus
Interface Module Test.