Symbol Technologies MC9000-G Benutzerhandbuch

Seite von 484
Configuring the Mobile Computer
10-11
If one of the partitions being built is the ESSID, a prompt appears requesting the ESSID 
value. Deselect the HR (High Rate) check box when building ESSID images for a device with 
an FH radio. 
Figure 10-6.  Build ESSID Partition Window
If one of the partitions being built is the Splash Screen, a prompt appears requesting both 
the source Bitmap file and the destination HEX file.
6.
A check is performed and if there are no errors, the partition hex files are created.
If the build fails, the hex files are not be created and TCM displays an error message. Two of the most 
common reasons for a build failure are:
Files defined in the script can not be found. This error can occur when the files referenced 
by the script are no longer stored on the development computer or the folders where they 
are stored were renamed.
The total amount of flash memory space required by the script exceeds the image size. To 
correct this, reduce the number of files in the partition or increase the size of the partition. 
See 
 for more information about setting the image 
size appropriately.
Sending the Hex Image
Once the hex file is built, it can be downloaded to the mobile computer.
To load the hex files on to the mobile computer:
1.
For downloads using a serial connection, connect the mobile computer to the development 
computer using the Single Slot Serial/USB cradle or CAM. 
2.
Press and hold the left scan button or the scan trigger and the Power button simultaneously 
until the mobile computer resets into IPL.