TECHNICAL FEATURES 
6.3  OM-GRYPHON™ / C-GRYPHON™ 
 
 OM-Gryphon™ 
C-Gryphon™ 
Electrical and General Features 
Supply Voltage 
9 to 28 Vdc 
Power Consumption (max) 
8 W (charging) * 
Indicators 
Battery Charging LED (red) 
Charge completed LED (green) 
Power/Data LED (yellow) 
Recharge Time 
NiMh batteries 
From 3 to 5 hours 
Host Interfaces 
 
RS232 
300 to 38400 baud 
9600 baud 
WEDGE 
IBM AT or PS/2, XT, PC 
Notebook, IBM SURE1, 
IBM 3153, 31xx, 32xx, 
34xx, 37xx terminals, 
Wyse terminals, 
Digital VT terminals, 
Apple ADB Bus 
Not supported 
PEN Emulation 
Selectable minimum pulse from 200 
µs to 1.2 ms 
Environmental Features 
Working Temperature 
0° to +40 °C / +32° to +104 °F 
Storage Temperature 
-20° to +70 °C / -4° to +158 °F 
Humidity 
90% non condensing 
Protection Class 
IP30 
Mechanical Features 
Weight (without cable) 
about 250 g. / 8.81 oz. 
Dimensions 
208 x 107 x 55.5 mm / 8.1 x 4.2 x 2.18 in 
Material ABS 
 
*  Having a switching regulator inside, the OM-Gryphon™ and C-Gryphon™ draw the 
same power, regardless of the supply voltage. i.e. as the input voltage increases 
the current drawn decreases. 
 
 